A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Assessment of cornea viability by confocal laser scanning microscopy and MTT assay. | LitMetric

Assessment of cornea viability by confocal laser scanning microscopy and MTT assay.

Cornea

Department of Biopharmaceutical Sciences, School of Pharmacy, University of California at San Francisco 94143-0446, USA.

Published: November 1997

Purpose: Determination of excised cornea viability is of interest for transplant-storage evaluation, but also for in vitro diffusion-study design and ocular-toxicity assessment. By using simultaneous vital staining by calcein AM (CAM) and ethidium homodimer-1 (EH-1), as "live" and "dead" probes, respectively, we developed a confocal laser scanning microscopy (CLSM) assay to determine epithelial and endothelial viability and estimate cornea thickness.

Methods: New Zealand White rabbit corneas were stored in phosphate-buffered saline (PBS) or Optisol at 4 degrees C or at room temperature. At various times, corneas were stained with an EH-1/CAM solution and observed, without further treatment, by CLSM. Storage effects on the cornea were also assessed by using an MTT assay.

Results: Stromal swelling, shedding of the upper epithelial layers, and severe endothelial damage were observed after 4 h in PBS at room temperature. After 8 h, lower epithelial cell death was observed, along with loss of endothelial structure. Corneas stored in similar conditions in Optisol were indistinguishable from controls. Storage in Optisol at 4 degrees C affected the superficial layers of the corneal epithelium similarly at both 7 and 14 days. Extensive epithelial shedding and wing-cell death were observed at 25 days, but the basal layer remained approximately 50% healthy. Significant endothelial cell loss was observed at 25 days. MTT results were consistent with CLSM data in the medium-term storage study only.

Conclusions: This CAM/EH-1 CLSM fluorescence assay is a sensitive index of viability in cornea, and thus may prove useful in investigations in which maintenance of vital functions in different cell layers is critical.

Download full-text PDF

Source

Publication Analysis

Top Keywords

cornea viability
8
confocal laser
8
laser scanning
8
scanning microscopy
8
corneas stored
8
optisol degrees
8
room temperature
8
death observed
8
observed days
8
observed
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!