Kinetic study of Russell's viper venom in envenomed patients.

Am J Trop Med Hyg

Department of Microbiology, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand.

Published: November 1997

Serum levels of Russell's viper venom in 30 patients bitten by Russell's viper were measured by an ELISA. In the initial serum samples, which were collected immediately after admission to the hospital (0.5-19 hr after the bite), venom was detected in 24 patients (80%), with levels ranging from 3 to 92 ng/ml. These levels correlated well with the patient's clinical signs. At 6-12 hr after antivenom therapy, the venom levels in most of the serum samples (21 of 24, 87%) had decreased to undetectable levels. In the remaining patients, whose serum venom levels could be detected 36-72 hr after therapy, the levels varied according to the effect of the antivenom therapy and the release of venom from a deposit at the bite site.

Download full-text PDF

Source
http://dx.doi.org/10.4269/ajtmh.1997.57.605DOI Listing

Publication Analysis

Top Keywords

russell's viper
12
viper venom
8
patients serum
8
serum samples
8
antivenom therapy
8
venom levels
8
levels
7
venom
6
kinetic study
4
study russell's
4

Similar Publications

This study examined the pathophysiological effects of venoms from neonate and adult specimens of the viperid snake , focusing on their ability to activate various blood clotting factors in human plasma. All venoms exhibited strong procoagulant properties. In concentration-response tests, the clotting potency of the neonate venoms fell within the range of their parents' maximum clotting velocities and areas under the curve.

View Article and Find Full Text PDF

Background: Snake bite is a well-known occupational hazard amongst farmers, plantation workers, and other outdoor workers and results in much morbidity and mortality throughout the world. The complications related to kidneys are observed in most patients with snake bites admitted to a hospital. The current study aimed to study the renal involvement in patients with snake bites with reference to clinical features and the time of onset of acute renal failure.

View Article and Find Full Text PDF

Objectives: This study aimed to analyse the epidemiological patterns of paediatric snake bites in Sri Lanka over a 4-year period (2020-2024).

Methods: A multi-centre, retrospective observational study was conducted from June 2020 to June 2024 across nine governmental hospitals in seven provinces of Sri Lanka. Data were collected based on 757 children presenting with snake bites.

View Article and Find Full Text PDF
Article Synopsis
  • - The article discusses lupus anticoagulant (LA), which is a phenomenon causing abnormal results in blood clotting tests, specifically highlighting its association with lymphoma and IgM paraproteinaemia.
  • - Two cases of low grade B-cell lymphoma were presented, both showing positive results for LA and a "lupus cofactor effect" in specific blood assays, indicating an unusual relationship between these conditions.
  • - The findings suggest that diluting patient samples with normal pooled plasma is crucial for accurately evaluating LA status in cases of low grade B-cell lymphoma, as certain tests may yield false negatives without dilution.
View Article and Find Full Text PDF

Detection of enoxaparin and argatroban by use of the novel viscoelastic coagulometer ClotPro.

Sci Rep

November 2024

Department of Anaesthesia, Intensive Care Medicine and Pain Medicine, Division of General Anaesthesia and Intensive Care Medicine, Medical University of Vienna, Währinger Gürtel 18-20, Wien, Vienna, 1090, Austria.

Article Synopsis
  • The study investigates point-of-care diagnostic tests for monitoring the anticoagulants enoxaparin and argatroban in critically ill patients who face risks of thrombosis and bleeding.
  • Blood samples from twelve healthy volunteers were used to evaluate the performance of the ClotPro viscoelastic coagulometer alongside traditional coagulation tests.
  • Results indicated that the RVV test for enoxaparin is not reliable, while the ECA test shows strong correlation and may be a better option for accurately detecting argatroban levels.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!