Unlabelled: We investigated the possibility of using argon, an inert gas, as a replacement for carbon dioxide (CO2). The tolerance of argon pneumoperitoneum was compared with that of CO2 pneumoperitoneum. Twenty pigs were anesthetized with enflurane 1.5%. Argon (n = 11) or CO2 (n = 9) pneumoperitoneum was created at 15 mm Hg over 20 min, and serial intravenous injections of each gas (ranging from 0.1 to 20 mL/kg) were made. Cardiorespiratory variables were measured. Transesophageal Doppler and capnographic monitoring were assessed in the detection of embolism. During argon pneumoperitoneum, there was no significant change from baseline in arterial pressure and pulmonary excretion of CO2, mean systemic arterial pressure (MAP), mean pulmonary artery pressure (PAP), or systemic and pulmonary vascular resistances, whereas CO2 pneumoperitoneum significantly increased these values (P < 0.05). During the embolic trial and from gas volumes of 2 and 0.2 mL/kg, the decrease in MAP and the increase in PAP were significantly higher with argon than with CO2 (P < 0.05). In contrast to CO2, argon pneumoperitoneum was not associated with significant changes in cardiorespiratory functions. However, argon embolism seems to be more deleterious than CO2 embolism. The possibility of using argon pneumoperitoneum during laparoscopy remains uncertain.

Implications: Laparoscopic surgery requires insufflation of gas into the peritoneal cavity. We compared the hemodynamic effects of argon, an inert gas, and carbon dioxide in a pig model of laparoscopic surgery. We conclude that argon carries a high risk factor in the case of an accidental gas embolism.

Download full-text PDF

Source
http://dx.doi.org/10.1097/00000539-199712000-00034DOI Listing

Publication Analysis

Top Keywords

argon pneumoperitoneum
20
co2 pneumoperitoneum
16
argon
11
co2
9
pneumoperitoneum
8
gas embolism
8
possibility argon
8
argon inert
8
inert gas
8
carbon dioxide
8

Similar Publications

Introduction: The paper presents unusual symptoms as a complication of therapeutic colonoscopy.

Case Report: A 70-year-old polymorbid female patient in chronic dialysis program underwent argon plasma coagulation treatment of leaking angioectasias in the cecum and ascending colon. Shortly after the procedure she presented with shortness of breath and subcutaneous emphysema of the neck which was initially misdiagnosed as swelling.

View Article and Find Full Text PDF

Background: This is the second update of a Cochrane Review first published in 2013 and last updated in 2017. Laparoscopic surgery is now widely performed to treat various abdominal diseases. Currently, carbon dioxide is the most frequently used gas for insufflation of the abdominal cavity (pneumoperitoneum).

View Article and Find Full Text PDF

Gases for establishing pneumoperitoneum during laparoscopic abdominal surgery.

Cochrane Database Syst Rev

June 2017

Department of Hepatobiliary Surgery, Yongchuan Hospital, Chongqing Medical University, No. 439, Quxuanhua Road, Chongqing, China, 402160.

Background: This is an update of the review published in 2013.Laparoscopic surgery is now widely performed to treat various abdominal diseases. Currently, carbon dioxide is the most frequently used gas for insufflation of the abdominal cavity (pneumoperitoneum).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!