Objective: To assess whether implantation in assisted reproductive technology (ART) cycles is a random event.

Design: Retrospective analysis of results.

Setting: Division for Reproductive Endocrinology and ART, Department of Obstetrics and Gynecology, Haemek Medical Center, Afula, Israel.

Patient(s): A cohort of all cycles reaching ET from July 1, 1995, through June 30, 1996, and a cohort of all pregnancies recorded from January 1, 1995, through October 31, 1996.

Intervention(s): None.

Main Outcome Measure(s): Rate of multifetal pregnancy in relation to overall pregnancy rate. The number of gestational sacs observed by sonography, out of transferred embryos in conception cycles, was defined as the individual implantation rate.

Result(s): Of 367 ETs, 75 (20.4%) yielded pregnancies, of which 31 (41%) were multifetal. Considering the mean number of embryos transferred (3.67), if implantation would have been random, multifetal gestation rate should have been only 14.8%, significantly less than the observed rate. In 110 pregnancies recorded between January 1995 and October 1996, individual implantation rate was 49.4% +/- 27.1% in intracytoplasmic sperm injection cycles compared with 40.5% +/- 20.4% in IVF cycles.

Conclusion(s): Embryo implantation is not a random event. The index of individual implantation rate may help shed light on mechanisms underlying implantation.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0015-0282(97)00356-7DOI Listing

Publication Analysis

Top Keywords

individual implantation
16
implantation rate
12
pregnancies recorded
8
recorded january
8
january 1995
8
1995 october
8
implantation random
8
rate
7
implantation
7
individual
4

Similar Publications

Purpose: Treatment of peripheral artery disease (PAD) in the region below the knee (BTK) is dissatisfying as failure of treated target lesions (TLF) is frequent and diagnostic imaging is often challenging. In the BTK-region metallic drug-eluting stents (mDES) yielded best results concerning primary patency (PP), but also annihilate signal in magnetic resonance angiography (MR-A). A recently introduced non-metallic drug eluting bioresorbable Tyrocore® vascular scaffold (deBVS), that offers an option for re-treatment of lesions due to its full degradation within 3-4 years after placement, was investigated with respect to its compatibility with MR-A to unimpededly depict previously treated target lesions.

View Article and Find Full Text PDF

Background: Low-profile double plating seems a viable alternative to conventional single plating for fixation of midshaft clavicle fractures. This study aims to compare the two techniques regarding healing, complications, and removal rate.

Methods: This retrospective cohort study included all patients >16 years that underwent plate fixation for midshaft clavicle fractures between 2020 and 2022 at one trauma-center.

View Article and Find Full Text PDF

Background: Neuroendocrine tumors of the thymus (NETT) are rare and malignant tumors that arise in the anterior mediastinum. These tumors can exhibit aggressive behavior and may involve surrounding critical structures, such as the superior vena cava. This case contributes to the literature by presenting a recurrent thymic carcinoma with invasion of major blood vessels, including the superior vena cava, and the complexities involved in its surgical management.

View Article and Find Full Text PDF

Purpose: The study assessed the clinical outcomes following treatment of peri-implant mucositis using Er:YAG laser or an ultrasonic device over six months. Patients' experience of pain, aesthetics, and Quality of life were further assessed.

Methods: One dental implant, per included patient, diagnosed with peri-implant mucositis underwent treatment with an Er:YAG laser (test) or an ultrasonic scaler (control) randomly.

View Article and Find Full Text PDF

Purpose: Preoperative virtual planning and osteosynthesis with patient-specific implants (PSIs) have become a quotidian approach to many maxillofacial elective surgery setups. When a process is well-organized, a similar approach can be harnessed to serve the needs of exact primary reconstructions, especially in midfacial trauma cases. PSI osteosynthesis of the mandible is, however, more challenging because a mirror technique of the facial sides is often unreliable due to inherent lack of symmetry, and movement of the mandible increases the risk of loosening of the osteosynthesis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!