A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Sysmex SE-9000 hematology analyzer: performance evaluation on leukocyte differential counts using an NCCLS H20-A protocol. National Committee for Clinical Laboratory Standards. | LitMetric

AI Article Synopsis

  • - The study assessed the performance of the Sysmex SE-9000 hematology analyzer for differential leukocyte counts, using a sample of 462 subjects and comparing its results with other methods like Bayer H6000, Coulter MAXM, and manual microscopy according to clinical guidelines.
  • - The SE-9000 showed low imprecision for most leukocyte subpopulations except for basophils, correlating well with other methods, although its measurement of neutrophils and lymphocytes had some discrepancies when compared to microscopic counts.
  • - The analyzer demonstrated good clinical sensitivity, particularly in detecting immature granulocytic cells, with an impressive agreement rate for distributional abnormalities (89.6%).

Article Abstract

We evaluated the performance (ie, imprecision, inaccuracy, and analytic sensitivity) of the Sysmex SE-9000 commercial hematology analyzer (TOA Medical Electronics, Kobe, Japan) on differential leukocyte counts according to the National Committee for Clinical Laboratory Standards H20-A protocol. The results obtained were compared with those from the Bayer H6000 and H3 (Bayer Diagnostic Division, Tarrytown, NY), the Coulter MAXM (Miami, Fla), and the microscopic method. Altogether, samples from 462 subjects were analyzed. The results show a substantial superimposition of reference intervals between the methods. The imprecision of the SE-9000 is low for all the leukocyte subpopulations, with the exception of basophils (coefficient of variation: neutrophils, 3.35%; lymphocytes, 4.25%; monocytes, 7.9%; eosinophils, 9.5%; and basophils, 44.2%) and is consistently lower than that of manual counts. The correlation with other methods is high, with the exception of basophils (r2: neutrophils, 0.94-0.95; lymphocytes, 0.93-0.97; monocytes, 0.76-0.85; eosinophils, 0.96-0.99; and basophils, 0.02-0.56). When compared with the microscopic method, an overestimation of neutrophils is seen mostly at low concentrations (mean difference, 2.63), and an underestimation of lymphocytes is seen at high concentrations (mean difference, -3.1). The clinical sensitivity was good, with an agreement of 75.7% on morphologic and 89.6% on distributional abnormalities. With a new analytical channel for immature cells (IMI), the analyzer shows high sensitivity in detecting immature cells of the granulocytic lineage (from 94.4% for immature granulocytes to 96% for myeloblasts).

Download full-text PDF

Source
http://dx.doi.org/10.1093/ajcp/108.6.674DOI Listing

Publication Analysis

Top Keywords

sysmex se-9000
8
hematology analyzer
8
h20-a protocol
8
national committee
8
committee clinical
8
clinical laboratory
8
laboratory standards
8
microscopic method
8
exception basophils
8
concentrations difference
8