The authors report the case of a young patient with an aneurysm of the ascending aorta and moderate aortic incompetence, who underwent a conservative operation at our institution. Dilatation of the sinotubular junction, particularly at the level of the non-coronary sinus of the aortic valve with loss of coaptation between the corresponding leaflet and the two coronary leaflets, was identified at the time of surgery as major cause of valve insufficiency. During surgery, the dilated ascending aorta and pathologic aortic sinus were replaced with a 26 Hemashield prosthesis tailored according to the David guidelines. An intraoperative post-repair transesophageal echo exam showed that the aortic valve appeared to be working competently. The post-operative course was uneventful and at one year, an echographic check of the aortic valve showed that it was fully competent, with normal leaflet motion. Conservative surgery can be a good option in selected patients with ascending aortic aneurysm and aortic valve insufficiency.

Download full-text PDF

Source

Publication Analysis

Top Keywords

aortic valve
20
ascending aorta
12
aneurysm ascending
8
aortic
8
valve insufficiency
8
valve
6
[reconstructive surgery
4
surgery case
4
case aneurysm
4
ascending
4

Similar Publications

A Novel Staging System of Cardiac Damage in Aortic Stenosis based on Multi-Chamber Myocardial Deformation.

Eur Heart J Cardiovasc Imaging

January 2025

Department of Cardiology, Istituto Auxologico Italiano, IRCCS, Milan, Italy.

Aims: This study evaluates whether multi-chamber myocardial deformation analysis using speckle tracking echocardiography (STE) can enhance validated current staging systems and improve risk stratification for patients with moderate-to-severe aortic stenosis (AS).

Methods And Results: We reanalyzed 2D, Doppler, and STE data obtained from two cohorts: derivation (654 patients, median age: 82 years; 51% men) and validation (237 patients, median age: 77 years; 55% men) with at least moderate AS (aortic valve area<1.5 cm2).

View Article and Find Full Text PDF

Objectives: The Ross procedure for aortic regurgitation (AR) and abnormal aortic valve morphologies is associated with an increased risk of autograft dilatation. Autograft support may ameliorate this problem. We analyzed the results for all haemodynamic lesions and the effect of autograft support.

View Article and Find Full Text PDF

Re-sheathing failure with Navitor during transcatheter aortic valve implantation: a case report.

Eur Heart J Case Rep

January 2025

The Second Department of Internal Medicine, University of Toyama, 2630 Sugitani, Toyama, Toyama 930-0194, Japan.

Background: Self-expanding valves used in transcatheter aortic valve implantation (TAVI) are designed to allow recapture and repositioning, facilitating optimal placement and mitigating conduction disturbances and paravalvular leakage. Here, we present a rare case in which the Navitor (Abbott Structural Heart, Santa Clara, CA, USA) could not be recaptured.

Case Summary: An 81-year-old Japanese woman with very severe aortic stenosis and a massively calcified nodule at the non-coronary cusp (NCC) underwent TAVI with a 25 mm Navitor valve.

View Article and Find Full Text PDF

Background: Since the transcatheter valve-in-valve (ViV) procedure was introduced in 2007, a few cases of infective endocarditis (IE) following the ViV procedure have been reported, which can be predisposed by older age, pre-existing medical conditions, and procedural techniques. Paravalvular abscesses constitute a rare complication of IE, resulting from extending IE beyond the valve annulus, less commonly caused by species. This complication is more common in prosthetic valves, particularly bioprosthetic valves.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!