There is increasing interest in both standardization and simplification of methods for enumeration of CD34+ hematopoietic progenitor cells (HPC) to facilitate cellular therapies and to improve interinstitutional comparison of clinical and laboratory results. We evaluated a novel method for CD34+ cell enumeration based on microvolume fluorimetry (MVF) compared with our laboratory's routine flow cytometric method on samples of peripheral blood and leukapheresis products. The MVF method is semiautomated and uses a 633-nm light from a helium-neon laser to scan fluorochrome-labeled cells held in stasis in a capillary known volume. The performance of the MVF assay for enumeration of CD34+ cells was found to be comparable to our routine flow cytometric assay in linearity and accuracy in the range of 5-1500 cells per microliter. Precision of MVF for replicate assays on the same instrument was demonstrated by coefficient of variation (CV) values of 8.4% at a CD34+ cell concentration of 284/microliters for a sample volume of 0.8 microliters, and 15.7% at 12/microliters for a sample volume of 3.2 microliter. Precision among three different instruments was demonstrated, using sample volumes of 1.6 microliters, by CV values of 44% at 6 cells/microliters and 4.6% at 733 cells/microliters. In a field sample evaluation, precision of the entire assay system for paired measurements on 0.8-microliter sample volumes was demonstrated by CV values of 50%, 31%, and 15% for peripheral blood samples with concentrations of 0-10, 10-20, and 20-100 CD34+ cells/microliters, respectively, and 6.3%, 8.1% and 6.5% for leukapheresis samples with concentrations of 0-100, 100-1,000, and 1,000-2,500 CD34+ cells/microliters, respectively. The MVF assay was easy to perform, required minimal technical training time, and had a turnaround time of 40 min, of which less than 10 min was actual technical time. These observations suggest that the MVF method for CD34+ cell enumeration may prove useful to clinical laboratories providing support for HPC collection, processing, and transplantation services that require relatively simple, rapid assays for product quality control or to guide real-time clinical decisions.

Download full-text PDF

Source
http://dx.doi.org/10.1089/scd.1.1997.6.291DOI Listing

Publication Analysis

Top Keywords

enumeration cd34+
12
peripheral blood
12
cd34+ cell
12
cd34+ hematopoietic
8
hematopoietic progenitor
8
progenitor cells
8
blood leukapheresis
8
leukapheresis products
8
microvolume fluorimetry
8
method cd34+
8

Similar Publications

In this study, we investigated the measurable residual leukemic stem cell (MR-LSC) population after allogeneic stem cell transplantation (allo-SCT) for high-risk acute myeloid leukemia (AML), utilizing T-cell immunoglobulin mucin-3 (TIM-3) expression as a functional marker of AML leukemic stem cells (LSCs). Analysis of the CD34CD38 fraction of bone marrow cells immediately after achievement of engraftment revealed the presence of both TIM-3LSCs and TIM-3 donor hematopoietic stem cells (HSCs) at varying ratios. Genetic analysis confirmed that TIM-3 cells harbored patient-specific mutations identical to those found in AML clones, whereas TIM-3 cells did not, indicating that TIM-3CD34CD38 cells represent residual AML LSCs.

View Article and Find Full Text PDF

Objectives: CD34+ hematopoietic stem cell (HSC) enumeration, crucial for HSC transplantation, is performed by flow cytometry to guide clinical decisions. Variability in enumeration arises from biological factors, assay components, and technology. External quality assurance schemes (EQAS) train participants to minimize inter-laboratory variations.

View Article and Find Full Text PDF

Background: Flow cytometry protocols for counting fresh CD34+ cell samples are not ideal for cryopreserved products due to cryoprotectant cytotoxicity. For cryopreserved samples, often large volumes of hypotonic solutions, which can cause cell death, are used to remove the cryoprotectant with a post-thaw wash. We recently developed a novel multistep dilution method with subsequent flow cytometry analysis to allow for accurate and reproducible results.

View Article and Find Full Text PDF

Background: This study aimed to compare the IMG counting by an auto hematology analyzer with the flow cytometric enumeration of CD34+ cells.

Methods: All data from 124 samples submitted to the hematology laboratory for CD34+ cell counting in 2019 and 2020 were retrospectively evaluated. Whole blood samples were taken into EDTA tubes and assayed within 2 hours.

View Article and Find Full Text PDF

Introduction: The CD34+ hematopoietic cell count was used to define cell harvest goals. Successful peripheral blood stem cell transplantation depends on infusion of an appropriate number of HPCs to achieve rapid and durable hematologic recovery.

Purpose: In this study, we evaluated the use of the Hematopoietic Progenitor Cell count program on the Sysmex XN-3000 hematology analyzer as an effective parameter for enumerating CD34+ cells.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!