A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[A malpositioned CVP catheter]. | LitMetric

[A malpositioned CVP catheter].

Masui

Department of Anesthesiology, Shimane Medical University, Izumo.

Published: October 1997

A 2-year-old boy was scheduled for patch closures of ASD and VSD. After anesthesia induction, infection of a double lumen central venous catheter (5 Fr, Arrow) was tried into the superior vena cava through the right jugular vein by Seldinger's method. We confirmed the placement of the catheter by drawing a small amount of blood. After the operation, chest X-ray examination in ICU revealed the misplacement of the catheter into his right intrapleural space. The catheter was left overnight to be used as a drainage route of a possible bleeding. Next morning, no abnormal finding in his chest X-ray and stable circulatory and respiratory conditions were found and we proceeded to extubate his endotracheal tube and take away the catheter. Two hours after the removal of the catheter, the boy showed forced respiration. He became cyanotic rapidly and then he needed emergency intubation. Following chest X-ray examination and an aspiration of intrapleural space revealed a severe hemothorax of the right side, where catheter had been inserted. The boy recovered without any disorders. This case suggests the importance to confirm the placement of CVP catheter, and to prevent the possible complications due to the malpositioned catheter.

Download full-text PDF

Source

Publication Analysis

Top Keywords

chest x-ray
12
catheter
9
x-ray examination
8
intrapleural space
8
malpositioned cvp
4
cvp catheter]
4
catheter] 2-year-old
4
2-year-old boy
4
boy scheduled
4
scheduled patch
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!