We describe a rapid and quantitative flow cytometric method for determining the apoptotic or anti-apoptotic potential of a gene in various cell types. A plasmid carrying green fluorescent protein (GFP) is co-transfected with an expression vector encoding the gene of interest. Subsequently cells are stained with propidium iodide and, utilising flow cytometry, transfected, GFP-expressing single cells are detected and apoptotic cells in this population are identified by their DNA content of <2 N. The method detects apoptosis as reliably as established methods using in situ nick-end labelling but is faster, easier and less expensive.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC147110PMC
http://dx.doi.org/10.1093/nar/25.23.4855DOI Listing

Publication Analysis

Top Keywords

rapid quantitative
8
flow cytometry
8
quantitative inexpensive
4
inexpensive method
4
method detecting
4
detecting apoptosis
4
apoptosis flow
4
cytometry transiently
4
transiently transfected
4
cells
4

Similar Publications

Barcoded Hybrids of Extracellular Vesicles and Lipid Nanoparticles for Multiplexed Analysis of Tissue Distribution.

Adv Sci (Weinh)

January 2025

Discovery Biology, Discovery Sciences, BioPharmaceuticals R&D, AstraZeneca, Pepparedsleden 1, Mölndal, 43150, Sweden.

Targeted delivery of therapeutic agents is a persistent challenge in modern medicine. Recent efforts in this area have highlighted the utility of extracellular vesicles (EVs) as drug carriers, given that they naturally occur in bloodstream and tissues, and can be loaded with a wide range of therapeutic molecules. However, biodistribution and tissue tropism of EVs remain difficult to study systematically.

View Article and Find Full Text PDF

Introduction: Qualitative and quantitative testing of ethanol in samples is an important analytical procedure that provides accurate, precise, and reliable results. Given the complexity of the issue, obtaining a realistic picture of lifelong alcoholemia requires supporting blood ethanol findings with analyses of alternative samples, primarily vitreous humor (VH).

Objective: The objective of this study was to develop and validate a headspace gas chromatography with flame ionization detection (HS/GC-FID) method for determining ethanol concentration in VH.

View Article and Find Full Text PDF

Rationale & Objective: Engaging patients with advanced chronic kidney disease (CKD) in goals of care (GOC) conversations is essential to align life-sustaining treatments with patient preferences. This pilot study described the feasibility of engaging older Veterans with advanced CKD in GOC conversations via telehealth by (1) comparing patient characteristics, including life-sustaining treatment note completion rates and preferences by visit modality, and (2) exploring Veteran and clinician perspectives surrounding telehealth GOC conversations.

Study Design: Mixed-method convergent design including a prospective, quantitative observational cohort analysis (n = 40) and qualitative, semi-structured interviews with 4 clinicians and 11 Veterans.

View Article and Find Full Text PDF

High temperature (HT) stress causes male sterility, leading to reduced upland cotton yield. Previously, we identified a key gene, Casein Kinase I (GhCKI), that negatively regulates male fertility in upland cotton under HT. However, conventional genetic manipulations of GhCKI would result in male sterility, hindering its utilization in breeding programs.

View Article and Find Full Text PDF

Polydopamine-encapsulated carbon dots to boost analytical performance for microplastics detection in fluorescence mode.

Mikrochim Acta

January 2025

School of Chemical Engineering and Technology, Hebei Key Laboratory of Functional Polymers, Hebei University of Technology, Beichen District, Xiping Road No. 5340, Tianjin, 300401, China.

A kind of sulfur-doped carbon dots was prepared which were encapsulated with polydopamine (S-CDs@PDA) that has fluorescence response on polyethylene (PE) microplastics (MPs). Modified membranes were constructed using S-CDs@PDA for MP detection. Through heating and vacuum filtration process, yellow emission from the modified membrane appeared because of the combination between S-CDs@PDA and PE MPs.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!