The authors evaluated the heat transfer characteristics of an electrohydraulic totally implantable artificial heart (EH-TAH) developed at our institute. In three in vitro experiments, the heat dissipation of the EH-TAH was investigated. First, the EH-TAH was connected to a closed mock circuit filled with 1 L of saline, and driven at an input power of 20 W. The estimated heat conducted to the blood was approximately 10.3 W, which was almost half of the input power. Second, we simulated heat transfer with the circulation of a calf by using a heat exchanger. The amount of heat dissipating directly from the EH-TAH surface was calculated to be 10 W. Third, the temperature of the actuator examined with thermography was found to be almost uniform, and no prominent high temperature area was observed. In an in vivo study, the EH-TAH was implanted for 10 days in a calf weighing 62 kg. The input power was 18 +/- 2 W, the temperature of the actuator-tissue contacting surface was 39.4 +/- 0.8 degrees C, and that of the pump blood chamber was 39.8 +/- 0.4 degrees C. This slight temperature elevation was thought to be attributable to heat dissipation to the blood. On histologic study of the chest wall and the lung in contact with the actuator, vascularized connective tissue envelopes were observed, but unfavorable side effects, such as tissue necrosis, were not observed. These results suggest that the thermal effect of this system is acceptable at the input power used.

Download full-text PDF

Source

Publication Analysis

Top Keywords

input power
16
heat dissipation
12
heat
8
electrohydraulic totally
8
totally implantable
8
implantable artificial
8
artificial heart
8
heat transfer
8
+/- degrees
8
eh-tah
5

Similar Publications

Although the Transformer architecture has established itself as the industry standard for jobs involving natural language processing, it still has few uses in computer vision. In vision, attention is used in conjunction with convolutional networks or to replace individual convolutional network elements while preserving the overall network design. Differences between the two domains, such as significant variations in the scale of visual things and the higher granularity of pixels in images compared to words in the text, make it difficult to transfer Transformer from language to vision.

View Article and Find Full Text PDF

Sparse wavefield reconstruction based on Physics-Informed neural networks.

Ultrasonics

January 2025

School of Mechanical and Power Engineering, Zhengzhou University, Zhengzhou 450001, China. Electronic address:

In recent years, the widespread application of laser ultrasonic (LU) devices for obtaining internal material information has been observed. However, this approach demands a significant amount of time to acquire complete wavefield data. Hence, there is a necessity to reduce the acquisition time.

View Article and Find Full Text PDF

In the Imbalanced Multivariate Time Series Classification (ImMTSC) task, minority-class instances typically correspond to critical events, such as system faults in power grids or abnormal health occurrences in medical monitoring. Despite being rare and random, these events are highly significant. The dynamic spatial-temporal relationships between minority-class instances and other instances make them more prone to interference from neighboring instances during classification.

View Article and Find Full Text PDF

General matrix multiplication (GEMM) in machine learning involves massive computation and data movement, which restricts its deployment on resource-constrained devices. Although data reuse can reduce data movement during GEMM processing, current approaches fail to fully exploit its potential. This work introduces a sparse GEMM accelerator with a weight-and-output stationary (WOS) dataflow and a distributed buffer architecture.

View Article and Find Full Text PDF

W-Band GaAs pHEMT Power Amplifier MMIC Stabilized Using Network Determinant Function.

Micromachines (Basel)

January 2025

Department of Radio and Information Communications Engineering, Chungnam National University, 99 Daehak-ro, Yuseong-gu, Daejeon 34134, Republic of Korea.

This paper presents a W-band power amplifier monolithic microwave integrated circuit (MMIC) that is designed for high-precision millimeter-wave systems and fabricated using a 0.1 µm GaAs pHEMT process. The amplifier's stability was evaluated using the network determinant function, ensuring robust performance under both linear and nonlinear conditions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!