Doppler echocardiography was applied to the assessment of patients with surgically documented St. Jude medical aortic valve dysfunction. Derivation of effective orifice area and Doppler velocity index with the continuity equation and calculation of valve resistance accurately differentiated stenotic from regurgitant and normal valves.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0002-9149(97)00652-8DOI Listing

Publication Analysis

Top Keywords

continuity equation
8
valve resistance
8
jude medical
8
aortic valve
8
valve dysfunction
8
application continuity
4
valve
4
equation valve
4
resistance evaluation
4
evaluation jude
4

Similar Publications

Continuous Near-Bed Movements of Microplastics in Open Channel Flows: Statistical Analysis.

Environ Sci Technol

January 2025

Department of Civil and Environmental Engineering, University of Alberta, Edmonton, Alberta T6G 1H9, Canada.

The ubiquitous distribution of microplastics (MPs) in aquatic environments is linked to their transport in rivers and streams. However, the specific mechanism of bedload microplastic (MP) transport, notably their stochastic behaviors, remains an underexplored area. To investigate this, particle tracking velocimetry was employed to examine the continuous near-bed movements of four types of MPs under nine setups with different experimental conditions in a laboratory flume, with an emphasis on their streamwise transport.

View Article and Find Full Text PDF

This study investigates the nonlinear dynamics of a system with frequency-dependent stiffness using a MEMS-based capacitive inertial sensor as a case study. The sensor is positioned directly on a rotating component of a machine and consists of a microbeam clamped at both ends by fixed supports with a fixed central proof mass. The nonlinear behavior is determined by electrostatic forces, axial and bending motion coupling, and frequency-dependent stiffness.

View Article and Find Full Text PDF

The aim of this study is to demonstrate the enhanced efficiency of combined therapeutic strategies for the treatment of growing tumors, based on computational experiments of a continuous-level modeling framework. In particular, the tumor growth is simulated within a host tissue and treated as a multiphase fluid, with each cellular species considered as a distinct fluid phase. Our model integrates the impact of chemical species on tumor dynamics, and we model -through reaction-diffusion equations- the spatio-temporal evolution of oxygen, vascular endothelial growth factor (VEGF) and chemotherapeutic agents.

View Article and Find Full Text PDF

To measure the electroacoustic parameters of transducers in the continuous sound field in a limited water area, a reciprocity calibration method of hydrophones using a spatial sampling average method in a non-anechoic tank was developed. The sound propagation in the non-anechoic tank under the impedance boundary condition, with a sound source producing continuous sound, is introduced based on the Helmholtz equation and Green's function. The reciprocity constant is given using the spatial sampling average sound pressure, and the three-transducer reciprocity calibration procedure was established.

View Article and Find Full Text PDF

Background: To investigate the effect of rheumatoid arthritis (RA) on the incidence of peri-implantitis (PI) and peri-implant mucositis (PIM).

Methods: Radiographic and clinical chart reviews were conducted to measure the probing depth (PD), bleeding on probing, and marginal bone loss (MBL) around the implants to diagnose peri-implant diseases based on the 2017 workshop classification. Values were recorded at the baseline (T0) to the last available chart and radiograph (T1).

View Article and Find Full Text PDF