The angular velocities of the hindlimb angles of 14 horses, including 6 Grand Prix dressage horses, 4 horses judged as good at the trot and 4 horses judged as poor, were analysed. The horse material was the same as previously used by Holmström (1994) in studies on conformation and trotting gaits in the Swedish Warmblood riding horse. Four consecutive strides of each horse and the corresponding pace were analysed and mean velocity curves (Xh) for each angle were calculated. Before calculation the data were filtered forwards and backwards with a Butterworth third order filter with a cut off frequency of 60 Hz. During the last 60% of the stance phase there were differences between the horses judged as good and poor at the trot in all the analysed hindlimb angles except the femur inclination. The angular velocity in the hock joint, pelvis inclination and hindlimb pendulation was larger in the good horses. The angular velocity of the hindlimb pendulation decreased with collection in the Grand Prix horses. During parts of the stance phase, there was also a gradual decrease in the femur angular velocity from trot at hand to piaffe. In the hock joint, there was no difference in angular velocity between trot at hand and passage during the last 30%. The higher compression of the hock angle and pelvic angle to the horizontal plane probably reflects a higher compression of the whole hindlimb. It probably contributes to the greater springiness in the movements of good young horses and Grand Prix dressage horses. The results from the present study confirmed the importance of storing elastic strain energy for the quality of the dressage horse gaits.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.2042-3306.1997.tb05056.xDOI Listing

Publication Analysis

Top Keywords

angular velocity
20
grand prix
12
horses judged
12
horses
10
horses angular
8
hindlimb angles
8
prix dressage
8
dressage horses
8
judged good
8
stance phase
8

Similar Publications

Objective: The detection of arterial pulsating signals at the skin periphery with Photoplethysmography (PPG) are easily distorted by motion artifacts. This work explores the alternatives to the aid of PPG reconstruction with movement sensors (accelerometer and/or gyroscope) which to date have demonstrated the best pulsating signal reconstruction.

Approach: A generative adversarial network with fully connected layers (FC-GAN) is proposed for the reconstruction of distorted PPG signals.

View Article and Find Full Text PDF

White Matter Fiber Bundle Alterations Correlate with Gait and Cognitive Impairments in Parkinson's Disease based on HARDI Data.

Curr Med Imaging

January 2025

Department of Radiology, Beijing Friendship Hospital, Capital Medical University, No. 95, Yong An Road, Xicheng District, Beijing 100050, China.

Background: The neuroanatomical basis of white matter fiber tracts in gait impairments in individuals suffering from Parkinson's Disease (PD) is unclear.

Methods: Twenty-four individuals living with PD and 29 Healthy Controls (HCs) were included. For each participant, two-shell High Angular Resolution Diffusion Imaging (HARDI) and high-resolution 3D structural images were acquired using the 3T MRI.

View Article and Find Full Text PDF

We introduce a novel, to the best of our knowledge, method to achieve a highly efficient nonreciprocal magnon laser within a spinning cavity optomagnonic system, which integrates a magnon mode and two optical modes. The rotation of the YIG sphere triggers the Barnett effect in the magnon mode and the Sagnac effect in the optical modes. The directional input of a pump light leads to opposite Sagnac-Fizeau frequency shifts in these modes.

View Article and Find Full Text PDF

Purpose: This study aimed to explore the association and prediction of hip abduction-adduction and knee flexion-extension isokinetic absolute and relative strength and power at 60°/s and 180°/s from functional tests performance (i.e., Up-and-Go Test [seconds], 30-Second Chair Stand Test [repetitions and relative and allometric power], 30-Second Arm Curl Test [repetitions], and 6-Minute Walk Test [meters]) in older adults.

View Article and Find Full Text PDF

To achieve rapid and stable detumbling of a space noncooperative satellite, an adaptive variable admittance control method for the manipulator is proposed and verified through simulation study and the ground experiment. The control block diagram of the proposed method is presented, and the adaptive variable admittance compliant detumbling control model is established. The proposed controller includes the fixed admittance controller in manipulator task space, the adaptive pose compensator for the grasping point on docking ring, and the damping adaptive regulator based on manipulator joint angular velocity, and the stability is proven by the Lyapunov method.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!