From July 1991 to March 1995, 178 patients who underwent 198 carotid surgical repairs were investigated preoperatively, intraoperatively, and postoperatively by transcranial Doppler sonography (TCD). Preoperative TCD evaluation showed stenosis of the middle cerebral artery (MCA) in 4 patients (2.2%), siphon stenosis in 3 (1.6%), incomplete circle of Willis in 23 (12.9%), a decrease of mean blood flow velocity more than 70% of the basal value during digital common carotid compression in 31 (17.9%), and a critical reduction of vasomotor reactivity (no significant increase of mean blood flow velocity in the MCA during breath-holding test) in 34 (19.1%). Nine patients (5%) had surgery without preoperative angiography. In those patients the indication for surgery was based on color Doppler imaging and TCD investigations. Ninety surgical procedures were carried out under general anesthesia and 188 under locoregional anesthesia. In 37 surgeries (31.7%) a shunt was inserted. The use of a shunt was based on a decrease of mean blood flow velocity in the MCA below 50% of the basal value under general anesthesia or loss of consciousness combined with a decrease of mean blood flow velocity in the MCA higher than 70% of the basal value when locoregional anesthesia was employed. Intraoperative TCD monitoring showed a decrease of mean blood flow velocity in the MCA due to shunt malfunction in (8.3%) of 36 surgeries, turbulence of blood flow during declamping in 79 procedures (39.8%), and microembolic events in 10 patients (5%) that were related to one transient and one permanent neurological deficit. Another permanent deficit occurred in a patient without TCD signs. After surgery, TCD reliably detected an early asymptomatic occlusion of the carotid artery, hyperperfusion syndrome in 12 (6.0%), and an increase of vasomotor reactivity in 10 (29.4%) of 34 surgeries.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/jon199774213 | DOI Listing |
Clin Drug Investig
January 2025
Department of Cardiology, Taleghani Hospital, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
Background: Primary percutaneous coronary intervention (PPCI) and fibrinolytic or thrombolytic therapy are common treatments for ST-elevation myocardial infarction (STEMI). Primary percutaneous coronary intervention is more effective than thrombolytic therapy, but fibrinolytic therapy is still a preferable option for patients with limited access to healthcare. Alteplase is a tissue plasminogen activator (tPA) used to treat acute myocardial infarction, acute ischemic stroke, and pulmonary embolism.
View Article and Find Full Text PDFAm J Physiol Heart Circ Physiol
January 2025
Interdisciplinary Stem Cell Institute, University of Miami Leonard M. Miller School of Medicine, Miami, Florida.
Swine are increasingly utilized in cardiovascular research due to their anatomical and physiological similarities to humans, particularly for studying diastolic dysfunction. While MRI offers excellent structural imaging, echocardiography provides superior real-time assessment of diastolic parameters. To address the lack of standardized methods and reduce variability across studies, we present a comprehensive guide for performing echocardiography in Yorkshire pigs, detailing anatomical considerations, equipment requirements, and technical approaches.
View Article and Find Full Text PDFClin Chem Lab Med
January 2025
Department of Nephrology, Ghent University Hospital Ghent, Belgium.
Objectives: We evaluated the performance of a novel flow cell morphology analyzer AUTION EYE AI-4510 for counting particles in urine.
Methods: Analytical performance was assessed according to the EFLM European Urinalysis Guideline 2023. Trueness was compared by analyzing 1.
J Appl Physiol (1985)
January 2025
Medical Physics Graduate Program, Duke University, Durham, North Carolina, United States.
Hyperpolarized Xe MRI/MRS enables quantitative mapping of function in lung airspaces, membrane tissue, and red blood cells (RBCs) within the pulmonary capillaries. The RBC signal also exhibits cardiogenic oscillations that are reduced in pre-capillary pulmonary hypertension (PH). This effect is obscured in patients with concomitant defects in transfer from airspaces to RBCs, which increase RBC oscillation amplitudes.
View Article and Find Full Text PDFNMR Biomed
March 2025
Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China.
In clinical practice, particularly in neurology assessments, imaging multiparametric MR images with a single-sequence scan is often limited by either insufficient imaging contrast or the constraints of accelerated imaging techniques. A novel single scan 3D imaging method, incorporating Wave-CAIPI and MULTIPLEX technologies and named WAMP, has been developed for rapid and comprehensive parametric imaging in clinical diagnostic applications. Featuring a hybrid design that includes wave encoding, the CAIPIRINHA sampling pattern, dual time of repetition (TR), dual flip angle (FA), multiecho, and optional flow modulation, the WAMP method captures information on RF B1t fields, proton density (PD), T1, susceptibility, and blood flow.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!