A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Size estimation method for patch used in reconstruction of LV cavity]. | LitMetric

[Size estimation method for patch used in reconstruction of LV cavity].

Nihon Kyobu Geka Gakkai Zasshi

Department of Cardiovascular Surgery, Yamagata Prefectural Central Hospital, Japan.

Published: September 1997

The reconstruction of LV cavity is accomplished by suturing a patch to the viable myocardium to exclude the infarcted area from the high LV pressures. However, there is no clear guideline to estimate the size of patch used for LV reconstruction. We have designed a new method to determine the correct patch size, and applied it in 5 cases. The suture line of the patch is at the junction of contractile (functional) and infarcted portions of LV. The patch size is determined by the length of AB, termed "a", as the base, where "point A" represents the junction on the LV anterior wall side, and "point B" the junction of the LV posterior wall side, from RAO 30 degrees projection of the left ventriculogram obtained by cardiac catheterization. In LV aneurysm, we designed the patch in the range of a/2 < l < or = pi a/2, where patch length on RAO 30 degrees is considered "l". An effort was made to reconstruct to normalize LV volume and contour by designing the patch size to be a/2 < l < a, particularly when the contractile portion was enlarged by aneurysm. On the other hand, in post AMI VSD, LV contractile portion is not enlarged in early stage. Therefore, the patch was designed in the range of a < l < or = pi a/2 to maintain LV volume. Postoperative LV volume can be calculated prior to surgery, by using the lengths of the designed patch. Postoperative analysis indicated that the actual LV volume and contour were almost identical to our estimation. This method is very useful in planning the patch size for LV reconstruction.

Download full-text PDF

Source

Publication Analysis

Top Keywords

patch size
16
patch
12
estimation method
8
patch reconstruction
8
wall side
8
rao degrees
8
designed patch
8
range a/2
8
volume contour
8
contractile portion
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!