Previous work with a 40-MHz continuous-wave Doppler ultrasound system has demonstrated the potential of high-frequency Doppler ultrasound (HFD), operating in the frequency range 20-200 MHz, to detect blood flow in the microcirculation. This paper describes a directional, pulsed-wave high-frequency Doppler ultrasound (PW HFD) system that was designed and constructed further to investigate this potential. The PW HFD system electronics have a dynamic range of > 80 dB, a noise floor of 250 nV, a directional isolation of 45 dB and operate over the frequency range 1-200 MHz. The system is tested using a focused PVDF transducer that is tuned for maximum sensitivity at 50 MHz, has a -6 dB lateral beamwidth of 70 microns and -6 dB depth-of-focus of 0.90 mm. This permits the practical use of sample volumes with dimensions 70 microns laterally by 90-900 microns axially. The PW HFD system can operate in duplex mode by either sharing the Doppler transducer or using a second PVDF transducer for imaging. Tests with string and capillary flow phantoms demonstrate that the PW HFD system is capable of detecting velocities on the order of the blood velocities found in the capillaries (0.5 mm/s) and arterioles (5 mm/s) with suitable velocity (30-300 microns/s) and temporal (15-100 ms) resolutions. In vivo measurements demonstrate that PW HFD can detect and measure blood velocities of less than 5 mm/s in arterioles and venules with diameters as small as 20 microns and 35 microns, respectively, using a sample volume of only 70 microns laterally by 150 microns axially. Preliminary experiments with high-frequency colour Doppler (HFCD) and high-frequency power Doppler (HFPD) imaging are also presented.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/s0301-5629(97)00076-8 | DOI Listing |
Anim Reprod Sci
January 2025
University of Georgia, Department of Animal and Dairy Sciences, Athens, GA 30602, USA. Electronic address:
This study evaluated the impact of luteal blood perfusion (BP) and expression of estrus on pregnancy rates of Bos taurus embryo recipients exposed to fixed-timed embryo transfer (FTET) using a gonadotropin-releasing hormone (GnRH)- and progesterone-based ovulation synchronization protocol. Postpartum beef cows (n = 746) were exposed to a GnRH/progesterone-based ovulation synchronization protocol. Luteal morphometry and BP were assessed using color Doppler ultrasonography 9 days after CIDR removal concurrently with FTET.
View Article and Find Full Text PDFSisli Etfal Hastan Tip Bul
December 2024
Department of General Surgery, Istanbul University, Istanbul Faculty of Medicine, Istanbul, Türkiye.
Inguinal masses have a large variety of causes, ranging from inguinal hernias to soft tissue sarcomas. One of the less prevalent causes is vascular origin. Venous aneurysms, unlike their arterial counterparts, are seen seldomly and experience in management of these cases is scarce.
View Article and Find Full Text PDFJ Sleep Res
January 2025
Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences (SIMATS), Saveetha University, Chennai, India.
Literature evidenced an association of maternal sleep disturbances and maternal obstructive sleep apnea with significant obstetric complications. Moreover, the maternal sleep disturbances effect on feto-placental circulation had not been extensively examined. Our objective is to explore the possible maternal sleep disturbances impact on the feto-placental indices evaluated through the Doppler study.
View Article and Find Full Text PDFUltrasound Obstet Gynecol
January 2025
Harris Birthright Research Centre for Fetal Medicine, King's College Hospital, London, UK.
Objective: Globally, one in four pregnant women is classified as overweight or obese, based on their prepregnancy body mass index (BMI). Obese pregnant women are at increased risk of adverse pregnancy outcomes and long-term cardiovascular disease that occurs earlier in life. This study aimed to assess maternal hemodynamic and vascular parameters at 35-37 weeks' gestation, to understand the alterations that may occur in association with increased maternal BMI and gestational weight gain, and to evaluate obesity-related pregnancy outcomes.
View Article and Find Full Text PDFJ Psychiatr Res
January 2025
Department of Radiology, Düzce University, Faculty of Medicine, Düzce, Türkiye.
Objective: The present study aims to investigate potential differences in cerebral blood flow between children with Cognitive Disengagement Syndrome (CDS) and those with Attention Deficit Hyperactivity Disorder (ADHD) using Doppler ultrasound.
Methods: In this single-center prospective study, we included 24 cases in the ADHD group with CDS symptoms, 29 cases in the ADHD group without CDS symptoms and, 26 children in the healthy controls. The children ranged in age from 6 to 15.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!