Objectives: We sought to evaluate the effects of intermittent transdermal nitroglycerin (TD-NTG) on the occurrence of ischemia during patch-off hours in patients with stable angina pectoris receiving a beta-adrenergic blocking agent or calcium antagonist, or both.
Background: The current recommendations for the use of intermittent TD-NTG may be associated with the occurrence of rebound ischemia.
Methods: This was a multicenter, randomized, double-blind, placebo-controlled, crossover trial with three study periods. Tolerability to TD-NTG was assessed in Period I. Seventy-two patients were assigned to receive either double-blind transdermal placebo or maximally tolerated TD-NTG for 2 weeks (Period II) and were then crossed over to the alternative treatment for another 2 weeks (Period III). The patients were instructed to apply medication daily at 8 AM, to remove it at 10 PM and to note symptoms and sublingual nitroglycerin (SL-NTG) use in a diary. The occurrence of ischemia was assessed from patient-perceived angina, symptom-limited exercise treadmill test (ETT) and 48-h ambulatory electrocardiographic (AECG) monitoring.
Results: Transdermal NTG (0.2 to 0.4 mg/h) significantly reduced the magnitude of ST segment depression at angina onset during ETT compared with placebo. Total angina frequency was not significantly different between TD-NTG (mean [+/-SD] 3.2 +/- 4.2) and placebo (3.3 +/- 5.2). During patch-off hours, angina frequency increased with TD-NTG (1.1 +/- 2.1) compared with placebo (0.7 +/- 1.6) (p = 0.03). Similar trends for an increase in ischemia after TD-NTG were also observed from AECG analyses. Specifically, ischemia frequency tended to be lower during patch-off hours for placebo than with TD-NTG (0.05 +/- 0.09 vs. 0.08 +/- 0.20 episodes/h, respectively, p = 0.08), even though frequency of ischemia tended to be higher during patch-on hours for placebo than with TD-NTG (0.12 +/- 0.19 vs. 0.07 +/- 0.15 episodes/h, respectively, p = 0.11). During placebo, ischemia frequency decreased 58% (patch-on to patch-off, p = 0.01) compared with a 14% increase with TD-NTG. These changes attenuate the usual circadian variation in ischemia.
Conclusions: An increase in ischemia frequency during patch-off hours after use of intermittent TD-NTG was perceived by patients, and this subjective finding was supported by a corresponding trend for AECG ischemia to increase during these same hours.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/s0735-1097(97)00268-4 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!