Purpose: To estimate the sensitivity and specificity of computed tomographic (CT) colography in detection of colorectal polyps and to compare these findings with those at axial CT.

Materials And Methods: In 70 consecutive patients, CT colography and colonoscopy were performed. Helical axial CT images and CT colographic images (multiplanar two- and three-dimensional endoluminal images) were evaluated separately by two radiologists blinded to results from colonoscopy and other imaging studies. Findings were compared with those at colonoscopy, which was the standard.

Results: The sensitivity and specificity for the two observers with CT colography averaged 75% and 90% in patients with adenomas 10 mm in diameter or larger, 66% and 63% in patients with adenomas 5 mm in diameter or greater, and 45% and 80% for patients with adenomas less than 5 mm in diameter, respectively. Sensitivity and specificity with axial CT were lower than those with CT colography (58% and 74%, respectively) in patients with adenomas 10 mm in diameter or larger.

Conclusion: Compared with axial CT, CT colography appears to have superior sensitivity and specificity in detection of clinically important colorectal adenomas. Early performance of CT colography seems promising for detection of colorectal polyps 5 mm and larger.

Download full-text PDF

Source
http://dx.doi.org/10.1148/radiology.205.1.9314963DOI Listing

Publication Analysis

Top Keywords

sensitivity specificity
20
patients adenomas
16
adenomas diameter
16
detection colorectal
12
colorectal polyps
12
colography
7
sensitivity
5
specificity
5
patients
5
adenomas
5

Similar Publications

Objective: This study evaluated the diagnostic value of plasma Neutrophil extracellular traps (NETs) levels and the index of cardiac electrophysiological balance (iCEB) in identifying silent myocardial ischemia (SMI) in maintenance hemodialysis (MHD) patients.

Methods: This cross-sectional observational study involved patients receiving MHD treatment. Data were collected on coronary angiography performed in our hospital from February 2023 to February 2024.

View Article and Find Full Text PDF

Background: Cardiac autonomic neuropathy (CAN) is a significant complication in chronic kidney disease (CKD), leading to increased morbidity and mortality. Early detection is essential for managing CKD patients effectively, especially those on hemodialysis. This study evaluated the prevalence CAN in CKD and diagnostic accuracy of Bellavere's Score in predicting CAN in CKD patients, including those undergoing hemodialysis.

View Article and Find Full Text PDF

Preparation and application of a multiepitope fusion protein based on bioinformatics and Tandem Mass Tag-based proteomics technology.

Front Immunol

January 2025

Jiangsu Engineering Research Center of Biological Data Mining and Healthcare Transformation, Xuzhou Medical University, Xuzhou, China.

Introduction: Brucellosis is a widespread zoonotic disease that poses a considerable challenge to global public health. Existing diagnostic methods for this condition, such as serological assays and bacterial culture, encounter difficulties due to their limited specificity and high operational complexity. Therefore, there is an urgent need for the development of enhanced diagnostic approaches for brucellosis.

View Article and Find Full Text PDF

Tuberculous meningitis diagnosis and treatment: classic approaches and high-throughput pathways.

Front Immunol

January 2025

Rehabilitation Medicine Department, The Affiliated Changsha Hospital of Xiangya School of Medicine, Central South University (The First Hospital of Changsha, Changsha, China.

Tuberculous meningitis (TBM), a severe form of non-purulent meningitis caused by (Mtb), is the most critical extrapulmonary tuberculosis (TB) manifestation, with a 30-40% mortality rate despite available treatment. The absence of distinctive clinical symptoms and effective diagnostic tools complicates early detection. Recent advancements in nucleic acid detection, genomics, metabolomics, and proteomics have led to novel diagnostic approaches, improving sensitivity and specificity.

View Article and Find Full Text PDF

Introduction: The establishment of a high-throughput quantification approach for waterborne pathogenic protozoa and helminths is crucial for rapid screening and health risk assessment.

Methods: We developed a high-throughput quantitative polymerase chain reaction (HT-qPCR) assay targeting 19 waterborne protozoa and 3 waterborne helminths and validated its sensitivity, specificity, and repeatability. The assay was then applied to test various environmental media samples.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!