Objective: We compared our ability to make iliac artery measurements on two-dimensional (2D) time-of-flight (TOF) and three-dimensional dynamic gadolinium-enhanced MR angiography with conventional angiography.

Subjects And Methods: Fifteen patients with lower extremity vascular disease underwent pelvic MR angiography. Parameters of the cardiac-gated axial 2D TOF sequence included a TR/TE of 24/7 msec and a 50 degrees flip angle. Parameters for the three-dimensional MR angiography sequence, in which we obtained 32 coronal 3-mm slices with fat suppression, included a TR/TE of 32/5 msec and a 40 degrees flip angle during infusion of 40 ml of gadolinium-chelated contrast material. Patients then underwent conventional angiography of the iliac arteries. Maximum stenosis in the common iliac, external iliac, and common femoral arteries was then measured. Measurements of stenosis were compared by repeated measures of analysis of variance. Sensitivity and specificity were calculated for identification of greater than or equal to 50% stenosis and less than 50% stenosis.

Results: For all vessels studied, we found no significant difference in measurements obtained from the gadolinium-enhanced MR angiography technique and those obtained from conventional angiography (p > .05). However, significantly different stenotic measurements were obtained from the 2D TOF MR angiography sequence and conventional angiography. In the external iliac arteries, 2D TOF MR angiography exaggerated stenoses most substantially. Gadolinium-enhanced MR angiography achieved 100% sensitivity and specificity.

Conclusion: Dynamic gadolinium-enhanced MR angiography was more accurate than 2D TOF MR angiography when measuring degree of stenosis in the iliac arteries.

Download full-text PDF

Source
http://dx.doi.org/10.2214/ajr.169.4.9308478DOI Listing

Publication Analysis

Top Keywords

gadolinium-enhanced angiography
20
angiography
13
dynamic gadolinium-enhanced
12
conventional angiography
12
iliac arteries
12
tof angiography
12
iliac artery
8
two-dimensional time-of-flight
8
three-dimensional dynamic
8
included tr/te
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!