Basic dosimetric quantities necessary to specify wedged beans (beam quality, wedge factors, output ratios) are obtained by measurements performed in a narrow coaxial mini-phantom for 6, 18 and 15 MV photon beams. To express beam quality, an attenuation coefficient mu is derived from measurements in a mini-phantom at 20 and 10 cm depth. Wedge factors and output ratios are measured as a function of field size at 10 cm water-equivalent depth. In open beams one observes beam softening with increasing distance from the collimator axis for all energies. With an inserted wedge a beam hardening is observed at 6 MV. This beam hardening decreases at 18 MV while at 25 MV a slight beam softening is detected. Larger variations of output ratios with field sizes are observed with a wedge than without a wedge. An equivalent square formula for head-scatter factors can be used with a good accuracy for rectangular wedged fields. For irregular wedged fields a method is proposed to calculate the product of the output ratio and the wedge factor. Measurements and calculations agree within 1% for all irregular wedged fields checked.

Download full-text PDF

Source
http://dx.doi.org/10.1088/0031-9155/42/9/012DOI Listing

Publication Analysis

Top Keywords

output ratios
12
wedged fields
12
photon beams
8
beam quality
8
wedge factors
8
factors output
8
beam softening
8
beam hardening
8
irregular wedged
8
beam
6

Similar Publications

In an era of interdisciplinary scientific research, new methodologies are necessary to simultaneously advance several fields of study. One such case involves the measurement of electron spin effects on biological systems. While magnetic effects are well known in biology, recent years have shown a surge in published evidence isolating the dependence on spin, rather than magnetic field, in biological contexts.

View Article and Find Full Text PDF

Objectives:  Antifibrinolytics, such as tranexamic acid (TXA), are widely used in cardiac surgery to reduce bleeding risks; however, the optimal dosage for TXA infusion remains a subject of debate. Hence, this study aims to evaluate the safety and efficacy of high-dose compared with low-dose TXA infusion in cardiac surgery patients.

Methods:  PubMed, SCOPUS, and Cochrane Central Register of Controlled Trials (CENTRAL) were searched until June 10, 2023, for studies assessing efficacy outcomes (e.

View Article and Find Full Text PDF

Nanosecond pulse power has many driving advantages in the dielectric barrier discharge (DBD) application field, including better discharge effect, higher discharge efficiency, and lower electrode temperature. A high-voltage pulse voltage power supply (HV-PVPS) with a multi-turn ratio linear pulse transformer (PT) based on Marx circuit and PT topologies are suitable for most DBD plasma applications with fewer expansion modules, lower cost, smaller volume, and higher reliability comparing with the all-solid-state Marx nanosecond pulse power supply. However, during the process of DBD driven by an HV-PVPS based on Marx and PT topologies, the PT is prone to magnetic core saturation, which limits the application for DBD.

View Article and Find Full Text PDF

Objective: This study aimed to systematically evaluate the safety of cyclosporine (CsA) and tacrolimus (TAC) in pediatric nephrotic syndrome (NS) patients using real-world data from the FDA Adverse Event Reporting System (FAERS).

Methods: We analyzed adverse event (AE) reports from the FAERS database between Q4 2003 and Q2 2024, focusing on AEs associated with CsA and TAC in NS patients aged 18 years and younger. We employed three signal detection methods-Proportional Reporting Ratio (PRR), Relative Reporting Ratio (RRR), and Reporting Odds Ratio (ROR)-to assess the risk of drug-related AEs.

View Article and Find Full Text PDF

Background: Cervical screening, aimed at detecting precancerous lesions and preventing cancer, is based on cytology and HPV testing. Both methods have limitations, the main ones being the variable diagnostic sensitivity of cytology and the moderate specificity of HPV testing. Various molecular biomarkers are proposed in recent years to improve cervical cancer management, including a number of mRNAs encoded by human genes involved in carcinogenesis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!