Purpose: To determine the prevalence of hepatitis B (HBV), hepatitis C (HCV), and human immunodeficiency virus (HIV) in the serum of cornea donors who had been previously screened by social and medical history by the Eye Bank of Canada, Ontario Division.

Method: A retrospective examination of the donor records of the Eye Bank of Canada, Ontario Division, was conducted. A total of 3,228 records were examined covering the period from May 17, 1993 to May 31, 1996.

Results: The prevalence of HBV was determined to be 0.25%, HCV, 0.93%; and HIV, 0.031%.

Conclusion: The data revealed that despite the use of medical and social history to prescreen, a small percentage of prescreened donors test serologically positive. A comparison of the prevalence of HBV, HCV, and HIV in the prescreened cornea donors to a similarly screened cohort of blood donors over a similar time period reveals a higher prevalence in all three diseases in the cohort of cornea donors. An examination of the demographic characteristics of the population as a whole versus the three groups with confirmed serology failed to show a significant difference between the seropositive and seronegative groups. This study confirms the value and necessity of serologic prescreening of cornea donors as is currently the standard of practice.

Download full-text PDF

Source

Publication Analysis

Top Keywords

cornea donors
20
medical social
8
social history
8
donors screened
8
eye bank
8
bank canada
8
canada ontario
8
prevalence hbv
8
donors
7
prevalence
5

Similar Publications

Objective: This study intended to assess willingness to donate eyes and associated factors among adults in Addis Ababa City, Ethiopia.

Methods And Analysis: This study used a triangulated phenomenological mixed-methods design, involving 1293 adults and eight key informants selected through multistage and purposive sampling. Data collection involved a pretested, semistructured questionnaire for quantitative data and an open-ended guiding questionnaire for qualitative insights.

View Article and Find Full Text PDF

Purpose: Conjunctival autografts (CAGs) are the gold standard treatment after pterygium resection, but it is challenging to achieve consistently thin Tenon-free CAGs with manual dissection. We herein report the reproducibility and clinical outcomes of a novel algorithm to produce customizable trapezoidal CAGs using femtosecond laser (femtosecond lasers)-assisted pterygium surgery.

Methods: We first tested this algorithm in 4 pig eyes to show reproducibility.

View Article and Find Full Text PDF

Lymphangiogenesis is vital for tissue fluid homeostasis, immune function, and lipid absorption. Abnormal lymphangiogenesis has been implicated in several diseases such as cancers, inflammatory, and autoimmune diseases. In this study, we elucidate the role of tsRNA-0032 in lymphangiogenesis and its molecular mechanism.

View Article and Find Full Text PDF

Biomimetic Air-Lifted Organ Culture System with a Protective Coverage Membrane for Full-Thickness Corneal Preservation.

ACS Biomater Sci Eng

January 2025

Shenzhen Key Laboratory of Smart Healthcare Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Department of Biomedical Engineering, Southern University of Science and Technology, Shenzhen, Guangdong 518055, China.

Effective storage and utilization of limited donor corneal resources are in high demand to alleviate the shortage of donor corneal tissue. Here, we designed a static air-lifted organ culture system equipped with a protective coverage membrane, namely, an air-lifted OC-P system, to provide a biomimetic physiological environment for full-thickness corneal preservation. The air-lifted OC-P system features a unique collagen-based protective coverage membrane that can offer a moist, oxygen-rich environment for corneal epithelium, produce an appropriate intraocular pressure onto the cornea by gravity, and facilitate the maintenance of the organ culture medium level for nutrient supply during corneal preservation.

View Article and Find Full Text PDF

: The aim of this study was to evaluate the effect of a surgical technique for managing post-penetrating keratoplasty (PK) ectasia complicated by late endothelial failure (LEF). : A single-center pilot case series was conducted regarding consecutive patients affected by post-PK ectasia with late graft failure. Using a microkeratome, a single donor cornea was dissected to prepare a two-piece graft, comprising a larger anterior lamella made up of anterior stroma and a smaller posterior lamella made up of posterior stroma, Descemet's membrane, and endothelium.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!