A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Amino acid determination in biological fluids by automated ion-exchange chromatography: performance of Hitachi L-8500A. | LitMetric

The Hitachi L-8500A is a newly available apparatus for amino acid (AA) analysis that allows automatic on-line mixing of the ninhydrin reagent. The within-run precision (human plasma pools at three different concentrations) showed CVs < 3.8% except for the lowest concentration of citrulline (4.4%), Tyr (4.5%), and alpha-aminobutyric acid (7.6%), and for the intermediate concentration of Asp (8.7%). Between-run precision (CV) was < 3.1% for 17 AAs and < 8.0% for 24 of 25 AAs (CV Asp = 12.0%). For retention times, within-run precision was < 0.4% and between-run precision < 1.8%. Excellent relations were found between the results from the Hitachi L-8500A and the widely used Beckman 6300 analyzer (0.929 < or = r < or = 0.999). The detection was still linear at 5 mumol/L except for Pro and hydroxyproline (20 mumol/L). The upper limit was at least 2500 mumol/L for 13 AAs and at least 1000 mumol/L for 27 of 29 AAs (anserine = 500, Val = 600 mumol/L). Values from 100 human plasma samples agreed with previously published data. We conclude that the results obtained with the Hitachi L-8500A are satisfactory when compared with those of other AA analyzers utilizing the same method. Furthermore, the Hitachi L-8500A displays several advantages including programming flexibility, microsample capacity, low noise plotting, ammonia filtering, and manual repacking of the analytical column.

Download full-text PDF

Source

Publication Analysis

Top Keywords

hitachi l-8500a
20
amino acid
8
within-run precision
8
human plasma
8
between-run precision
8
mumol/l aas
8
hitachi
5
l-8500a
5
mumol/l
5
acid determination
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!