Biplane transesophageal echocardiography in the normal cat.

Vet Radiol Ultrasound

Department of Medicine and Epidemiology, School of Veterinary Medicine, University of California Davis 95616, USA.

Published: September 1997

Eight healthy, adult cats were examined with biplane transesophageal echocardiography (TEE). Cats were sedated with a combination of diazepam and propofol and were examined using a 5 mm x 80 cm pediatric biplane TEE probe. Consistent images were obtained at three imaging depths within the esophagus. The caudal position provided satisfactory short-axis images of the left ventricle and heart base. The middle position provided the best long-axis views of the left atrium, left ventricle, and aorta and allowed Doppler examination of transmitral left ventricular inflow. The cranial position provided satisfactory imaging of the aorta and pulmonary artery and allowed Doppler examination of right ventricular and left ventricular outflow. Biplane TEE provides an additional method of imaging the feline heart which is complimentary to other imaging techniques and the images obtained were similar to those reported for dogs. Although TEE offers a slight advantage over transthorcic imaging for Doppler examination, the quality of the images of heart base structures was not as consistently superior to transthoracic images in cats as reported in dogs.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1740-8261.1997.tb00858.xDOI Listing

Publication Analysis

Top Keywords

position provided
12
doppler examination
12
biplane transesophageal
8
transesophageal echocardiography
8
biplane tee
8
provided satisfactory
8
left ventricle
8
heart base
8
allowed doppler
8
left ventricular
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!