Diagnostic accuracy of a rural live video telepathology system.

Am J Surg Pathol

Department of Pathology, Fletcher Allen Health Care, Burlington, Vermont, USA.

Published: July 1997

Accuracy of diagnoses rendered using a live video telepathology network was assessed for permanent sections of surgical pathology specimens. To determine accuracy, telepathology diagnoses were compared with those obtained by directly viewing the glass slide using a standard microscope. A total of 294 cases were read via both telepathology and glass slide by attending pathologists at a tertiary care medical center. Overall accuracy was defined as exact concordance between diagnoses. Clinically insignificant differences in diagnoses were excluded to determine clinically significant accuracy. For the 285 cases with complete data, the overall accuracy for telepathology was 0.912 (95% confidence interval [CI], 0.872-0.941), whereas the overall accuracy for glass slide readings was 0.968 (95% CI, 0.939-0.985). This difference is statistically significant (p = 0.009). When focusing on clinically significant discrepancies, where the difference in diagnosis might affect therapeutic decisions, the video accuracy was only slightly less than the glass slide accuracy (0.965 [95% CI, 0.934-0.982] vs. 0.982 [95% CI, 0.957-0.994], respectively), but this difference is not statistically significant (p = 0.302). Most of the cases with clinically significant differences involved lesions with inherently high interobserver variation. Certainty of diagnosis did not differ between video and glass slide readings (p = 0.911), but there was an association between certainty of diagnosis and diagnostic accuracy for video (p = 0.003 for clinically significant accuracies). Based on these findings, we recommend when using this telepathology system that only preliminary diagnoses should be given in the following situations: for diagnostic areas with known high interobserver variability; when the consultant has any degree of uncertainty about the presence or absence of the lesion in question; and when there is insufficient experience using telepathology as a diagnostic medium.

Download full-text PDF

Source
http://dx.doi.org/10.1097/00000478-199707000-00009DOI Listing

Publication Analysis

Top Keywords

glass slide
20
accuracy
9
diagnostic accuracy
8
live video
8
video telepathology
8
telepathology system
8
accuracy telepathology
8
accuracy glass
8
slide readings
8
difference statistically
8

Similar Publications

Robust, Fluorine-Free Superhydrophobic Films on Glass via Epoxysilane Pretreatment.

Langmuir

January 2025

Materials Chemistry Centre, Department of Chemistry, University College London, 20 Gordon Street, London WC1H 0AJ, U.K.

Durable and fluorine-free superhydrophobic films were fabricated by a simple two-step process involving the pretreatment of glass substrates with an epoxysilane, which acted as an adhesive. The next step involved the aerosol-assisted chemical vapor deposition of a simple mixture of polydimethylsiloxane (PDMS) and SiO nanoparticles (NPs). Various parameters were studied, such as deposition time as well as PDMS and SiO loadings.

View Article and Find Full Text PDF

Fingermarks are important forensic evidence for identifying people. In this work, luminescent MOF [Eu(BDC)(HO)] (herein referred as EuBDC) was tested as a potential latent fingermark (LF) luminescent developer powder and its acute toxicity evaluated following OECD protocol 423. The results showed that the powder can develop groomed LF on materials such as leather, plastic, metal, glass, cardboard, and aluminum.

View Article and Find Full Text PDF

Acute leukemia (AL) is a diverse group of hematological malignancies characterised by the accumulation of immature blast cells in the bone marrow. Accurate classification into acute myeloid leukemia (AML) or acute lymphoblastic leukemia (ALL) is essential for treatment and prognosis. This study aimed to assess the performance of glass slide morphology (GSM) using a light microscope versus whole slide imaging (WSI) in diagnosing and classifying AL, using flow cytometry as the gold standard test.

View Article and Find Full Text PDF

Dynamic Covalent Sulfur-Selenium Rich Polymers via Inverse Vulcanization for High Refractive Index, High Transmittance, and UV Shielding Materials.

Macromol Rapid Commun

January 2025

College of Chemistry and Chemical Engineering, Gansu International Scientific and Technological Cooperation Base of Water-Retention Chemical Functional Material, Northwest Normal University, Lanzhou, Gansu, 730070, P. R. China.

Recent advancements in inverse vulcanization have led to the development of sulfur-rich polymers with diverse applications. However, progress is constrained by the harsh high-temperature reaction conditions, limited applicability, and the generation of hazardous HS gas. This study presents an induced IV method utilizing selenium octanoic acid, yielding sulfur-selenium rich polymers with full atom economy, even at a low-temperatures of 100-120 °C.

View Article and Find Full Text PDF

GNCnn: A QuPath extension for glomerulosclerosis and glomerulonephritis characterization based on deep learning.

Comput Struct Biotechnol J

December 2024

VISILAB Group, Universidad de Castilla-La Mancha, Av. Camilo José Cela, Ciudad Real, 13071, Ciudad Real, Spain.

The digitalization of traditional glass slide microscopy into whole slide images has opened up new opportunities for pathology, such as the application of artificial intelligence techniques. Specialized software is necessary to visualize and analyze these images. One of these applications is QuPath, a popular bioimage analysis tool.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!