An immunoradiometric method of the second generation (IR-MA II) is widely used to determine CA125 serum levels. In this study we have evaluated the performance characteristics of a commercially available IRMA CA125 II (Byk-Gulden, Sangtec Diagnostica). The CA125 serum levels were determined in several groups of patients (healthy women, pregnant women, subjects affected by benign and malignant ovarian cancer, patients with liver diseases) with two IRMAs CA125 II (Byk-Gulden, Sangtec Diagnostica and Centocor, Diagnostic Division) and IRMA CA125 I (Byk-Gulden, Sangtec Diagnostica). Our results show a good analytic performance of IRMA CA125 II (Byk-Gulden, Sangtec Diagnostica), a good correlation between IRMAs CA125 II (Byk-Gulden, Sangtec Diagnostica and Centocor, Diagnostic Division), but an unacceptable correlation between IRMAs CA125 II (Byk-Gulden, Sangtec Diagnostica and Centocor, Diagnostic Division) and IRMA CA125 I. A statistically significant difference was observed comparing the values obtained with both IRMAs CA125 II and IRMA CA125 I in the groups of patients. In contrast no statistically significant difference was observed when we compared the values obtained with IRMA CA125 II (Byk-Gulden, Sangtec Diagnostica) and IRMA CA125 II (Centocor, Diagnostic Division). CA125 serum values obtained with the second-generation kits were different from those obtained with the first-generation one; consequently, it is important, especially in the follow-up of cancer patients, that CA125 serum values be obtained with kits of the same generation. Our data seem to suggest the use of second-generation kits to determine CA125 serum levels.

Download full-text PDF

Source
http://dx.doi.org/10.1177/030089169708300223DOI Listing

Publication Analysis

Top Keywords

irma ca125
28
ca125 byk-gulden
28
byk-gulden sangtec
28
sangtec diagnostica
28
ca125 serum
20
serum levels
16
ca125
16
irmas ca125
16
centocor diagnostic
16
diagnostic division
16

Similar Publications

Random Assay in Radioimmunoassay: Feasibility and Application Compared with Batch Assay.

Nucl Med Mol Imaging

December 2016

Department of Nuclear Medicine, National Cancer Center, 323 Ilsan-ro, Ilsandong-gu, Goyang-si, Gyeonggi-do 410-769 Republic of Korea.

Purpose: The batch assay has been conventionally used for radioimmunoassay (RIA) because of its technical robustness and practical convenience. However, it has limitations in terms of the relative lag of report time due to the necessity of multiple assays in a small number of samples compared with the random assay technique. In this study, we aimed to verify whether the random assay technique can be applied in RIA and is feasible in daily practice.

View Article and Find Full Text PDF

Serum HE4 levels combined with CE CT imaging improve the management of monitoring women affected by epithelial ovarian cancer.

Oncol Rep

November 2013

Department of Radiological, Oncological and Anatomopathological Sciences, 'Sapienza' University, Umberto I Hospital, I-00161 Rome, Italy.

The aim of the present study was to evaluate human epididymis protein 4 (HE4) as a marker of epithelial ovarian cancer (EOC) relapse and the combination of this biomarker with contrast-enhanced high-resolution multidetector row computed tomography CE CT imaging to impove the monitoring of EOC patients. Twenty-one patients with advanced EOC (FIGO III/IV) who underwent surgery and adjuvant chemotherapy were retrospectively selected. Each patient contributed 3 serum samples drawn at 3-month intervals: time interval I (1-3 months from surgery), time interval II (4-6 months from surgery) and time interval III (7-10 months from surgery).

View Article and Find Full Text PDF

Objective: To evaluate the clinical value of autoantibody spectrum against ovarian cancer associated antigens combine CA(125) in detecting and monitoring ovarian cancer.

Methods: Circulating IgG, IgM autoantibodies against ovarian cancer associated antigens which included TM4SF1, C1D, TIZ, OV-142, FXR1 and OV-189 were measured by indirect ELISA in serum from 126 patients with ovarian cancer (prior treatment), 42 patients with benign ovarian masses, 142 healthy women. Cut off value of IgG, IgM autoantibodies were determined by receive operating characteristic (ROC) curve.

View Article and Find Full Text PDF

Human epididymis protein 4 (HE4) has recently been described as a new marker for the early diagnosis of ovarian cancer (OC). The objective of this study was to evaluate (a) the expression of HE4 vs. OC mucin CA125 in 32 patients with OC compared to 163 patients with other malignant or benign pathologies (b) HE4 as indicator of the recurrence of the disease in eight patients followed-up for 20 months after OC diagnosis.

View Article and Find Full Text PDF

Cytosolic levels of neuron-specific enolase in squamous cell carcinomas of the lung.

Int J Biol Markers

May 2004

Nuclear Medicine Service, University Hospital, Complejo Hospitalario Universitario, Santiago de Compostela, Spain.

To study the behavior and possible correlations of neuron-specific enolase (NSE) with other clinicobiological parameters, we measured the cytosolic levels of this marker by means of an immunoradiometric assay (IRMA) in 95 squamous cell lung carcinoma samples. We also analyzed the levels of pS2, tissue-type plasminogen activator (t-PA), hyaluronic acid (HA), free beta subunit of human chorionic gonadotropin (beta-HCG), CYFRA 21.1 and CA 125 in cytosol.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!