Resorbable fixation plates in head and neck surgery.

Laryngoscope

Department of Otolaryngology-Head and Neck Surgery, Indiana University Medical Center, Indianapolis, U.S.A.

Published: June 1997

A skeletal fixation system employing plates made of polylactic and polyglycolic acid has been employed at Indiana University Medical Center since July 1993 in 105 craniofacial reconstructions, 45 cases of maxillofacial trauma, 10 craniotomy flap repairs, and five cases involving reconstruction of the laryngotrachea. Because these plates eventually resorb, they offer significant theoretical advantages. No inhibition of structural growth should occur when using this system in children. Tissue tolerance of these plates has been excellent. The technical details of using heat to allow reshaping of the plates as well as the methods of fixation of the plates are discussed.

Download full-text PDF

Source
http://dx.doi.org/10.1097/00005537-199706000-00003DOI Listing

Publication Analysis

Top Keywords

fixation plates
8
plates
6
resorbable fixation
4
plates head
4
head neck
4
neck surgery
4
surgery skeletal
4
skeletal fixation
4
fixation system
4
system employing
4

Similar Publications

Objective: To observe the clinical outcomes of anterior approach for the revision surgery following unsuccessful bone cement augmentation in osteoporotic vertebral compression fractures.

Methods: A total of 10 patients who experienced unsuccessful bone cement augmentation underwent anterior revision surgery between January 2020 and December 2021. There were 2 males and 8 females.

View Article and Find Full Text PDF

Objective: Meta-analysis of the clinical efficacy of plate and external fixator fixation in the treatment of AO-C type distal radius fractures.

Methods: PubMed, Embase, Cochrane Medical Library, Web of Science, CNKI, Wanfang, VIP and SinoMed databases were searched for all literature on randomized controlled clinical trials of AO-C distal radius fractures. The search time limits were from each database.

View Article and Find Full Text PDF

Objective: To investigate the effects of bone density, plate bending degree and proximal screw type on the stress fracture of clavicle hook.

Methods: Three sows weighing between 45 and 50 kg were selected, from which a total of 40 rivs were collected. The 15 ribs of sows were divided into 3 groups according to bone density and bone hardness with 5 rivs in each group.

View Article and Find Full Text PDF

Objective: To investigate the clinical efficacy of thoracoscopic minimally invasive surgery with nickel-titanium shape memory alloy wrap bone plate versus rib periosteal internal fixation in patients with multiple rib fractures (MRF) and flail chest.

Methods: A retrospective analysis was performed on 100 patients with MRF and flail chest treated with thoracoscopic minimally invasive surgery and internal fixation with rib fracture preservation between January 2019 and December 2022, including 54 males and 46 females, aged from 20 to 65 years old, with an average age of (38.0±18.

View Article and Find Full Text PDF

Objective: To compare the short-term clinical efficacy and safety of closed reduction with Kirschner wire fixation versus open reduction with plate fixation for treating osteoporotic Colles' fractures in middle-aged and elderly patients.

Methods: Between January 2018 and January 2023, 119 patients with Colles fractures were retrospectively analyzed, including 39 males and 80 females, aged from 48 to 74 years old with an average of(60.58±6.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!