Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: The first goal of phase I drug development is the determination of maximal tolerated dose, which must be established by case-by-case analysis, sometimes using a laboratory adverse event. Since no accurate rule defining lab adverse events, has been validated yet, we propose a new "combined method" based on combination of two thresholds: inclusion values and magnitude of variation. Using this combined method, the label "lab adverse event" is applied if any lab value exceeds the inclusion threshold and is associated with a variation from baseline exceeding the variation threshold defined from reference change limit. Thus, this study aimed to test this combined method on a large healthy volunteer population, studied in 19 phase I centres worldwide, and on five lab parameters: alanine amino transferase, aspartate amino transferase, alkaline phosphatases, creatinine and polymorphonuclear leukocytes.
Methods: The inclusion threshold from each center was used. Reference change limits were defined from volunteers previously included in comparable studies and were expressed as absolute values: increases of 10 IU.l-1 for alanine amino transferase or aspartate amino transferase, 15 IU.l-1 for alkaline phosphatases, 15 mumol.l-1 for creatinine and a 0.34 10(9).l-1 decrease for polymorphonuclear leukocytes. Comparison between the "combined method" and a normal range method was made using positive predictive value and a ratio between relevant and irrelevant results. This application was implemented in all young healthy volunteers (1134) included in 38 phase I studies sponsored by Rhone Poulenc Rorer from 1991 to 1993.
Results: Seventy seven subjects (6.7%) were indicated in final study reports as having a lab adverse event (reference group). Of 179 subjects with lab abnormalities defined by the normal range method, 77 belonged to the reference group, inducing a poor 0.43 positive predictive value. Of ninety subjects with lab adverse events defined by the "combined method", seventy-five belonged to the reference group, inducing a two-fold higher 0.83 positive predictive value. The combined method produced a high ratio of relevant/irrelevant results (5 = 75/15) compared with the low ratio (0.76 = 77/102) achieved using the normal range method.
Conclusion: This new "combined method", leading to a better definition of lab adverse event, seems an accurate and useful tool for routine case-by-case analysis within phase I drug development studies.