HPLC resolution of C5 chiral 4,5-dihydro-1,4-benzodiazepines: stereochemical characterization and enantioselective GABAA receptor binding.

J Pharm Biomed Anal

Centro Studio CNR Macromolecole Stereordinate Otticamente Attive, Dipartimento di Chimica e Chimica Industriale, Pisa, Italy.

Published: March 1997

HPLC resolution on chiral stationary phases has been successfully employed to obtain single enantiomers of C5 chiral 4,5-dihydro-1,4-benzodiazepines and to determine the enantiomeric composition of the collected stereoisomeric fractions. The absolute configuration of the prevailing enantiomer has been assigned on the basis of the circular dichroism spectra, as compared with that of the structural analogue (5R)- and (5S)-dihydrodiazepam. The single enantiomers, assayed for their binding to the central nervous system receptor, showed relatively low affinity but significant differences in displacing radioactively labelled flunitrazepam from specific benzodiazepine site. GABA shift experiments allowed the classification of these benzodiazepines as partial agonist or antagonist.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0731-7085(96)01908-5DOI Listing

Publication Analysis

Top Keywords

hplc resolution
8
resolution chiral
8
chiral 45-dihydro-14-benzodiazepines
8
single enantiomers
8
45-dihydro-14-benzodiazepines stereochemical
4
stereochemical characterization
4
characterization enantioselective
4
enantioselective gabaa
4
gabaa receptor
4
receptor binding
4

Similar Publications

The influence of additives and modifiers on the chiral HPLC separation of the nicotine enantiomers using UV/Vis detection is discussed. Selected alcohols as modifiers and selected amines as additives were found to have a significant effect on the resolution and retention times of nicotine enantiomers even to the point of eliminating component elution. Systematic variations in the concentration of ethanol, methanol, and isopropanol, as modifiers, along with variations in the concentration of diethylamine, triethylamine, tributylamine, ethylenediamine, isopropylamine, as additives, revealed that the average resolution (R) of the nicotine enantiomers ranged from 2.

View Article and Find Full Text PDF

Comment on "Stability and degradation mechanism of (-)-epicatechin in thermal processing".

Food Chem

January 2025

Poznań University of Technology, Institute of Chemistry and Technical Electrochemistry, Berdychowo 4, 60-965 Poznań, Poland. Electronic address:

Catechins, due to their high antioxidant capacity, are ones of the most common ingredients of human diet (e.g. tea, fruits, cacao) of the well-known health benefit properties.

View Article and Find Full Text PDF

Resorcinol is a widespread substance used in a large variety of manufacturing industries, including cosmetics, with endocrine-disrupting activity on the thyroid function. The aim of the present study was to develop and validate a sensitive, selective and robust method to quantify resorcinol in urine and thereby assess hairdressers' occupational exposure. As resorcinol is mainly excreted in urine as glucuronide or sulfate forms, the first step consisted in hydrolyzing urine samples with a β-glucuronidase-arylsulfatase enzyme for 16 h.

View Article and Find Full Text PDF

The members of the genus Mill. are notable for producing a diverse range of structurally intricate secondary metabolites, being the focus of current phytochemical research. Their importance is recognized as several species hold significant ethnopharmacological value, being traditionally used to address ailments in human systems, such as respiratory, gastrointestinal, and urinary conditions, among others.

View Article and Find Full Text PDF

Exploring tazarotene, a third-generation retinoid for potential hand osteoarthritis treatment, this study presents the development and validation of an ultra-performance liquid chromatography with quadrupole detector mass spectrometry (UPLC-QDa) method for the simultaneous quantification of tazarotene and tazarotenic acid, its active metabolite, in porcine skin. Method development involved a design-of-experiments approach for chromatographic optimization of gradient steepness, organic solvent volume, column temperature, capillary voltage, flow rate, and cone voltage. Central composite orthogonal design was used to optimize peak area, peak width, retention time, and resolution.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!