A novel piezo-electric force transducer was developed that is mounted directly on ITI-implants and allows for simultaneous force measurements in 3 dimensions. The reliability of this measuring method in vitro and in vivo was evaluated. For test and calibration measurements 5 edentulous patients with 2 mandibular implants were selected and master casts obtained with original implants in situ. Preload of the abutment screw was measured with a torque controller by repeated tightening and loosening. The introduction of additional preloads when bar connectors or telescopes were mounted was examined on the casts and in the mouth. Tests were carried out to identify the influence of screw tensions on force measurements by loading the implants in vertical and transverse directions. Calibration measurements in vivo and in vitro were carried out by means of a spring balance. A regression model was calculated to analyze the influence of the applied preload on measured forces. The mean preload value was 315, ranging from 200 to 480N. A significant correlation of applied loads to measured forces was found (r = 0.99). It was independent of the preload in vertical direction but dependent in transverse direction. No additional tension of the abutment screw was ever observed when bars were mounted. Calibration measurements with the spring balance showed that bars contribute to load sharing between the implants. Comparable results were found for all measurements in vitro and in vivo. It was concluded that the new piezo-electric transducer is an adequate instrument to measure forces in 3 dimensions on ITI-implants.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1034/j.1600-0501.1996.070412.x | DOI Listing |
Exp Brain Res
January 2025
Department of Rehabilitation Medicine, The First Affiliated Hospital of Sun Yat-Sen University, Guangzhou, Guangdong, 510080, China.
Vestibular dysfunction has been reported as a potential cause in adolescent idiopathic scoliosis (AIS). However, it remained unclear how stochastic galvanic vestibular stimulation (GVS) affected kinetic performance of patients with AIS. This study aimed to investigate the effect of stochastic GVS on ground reaction forces (GRF) measures during obstacle negotiation among patients with AIS.
View Article and Find Full Text PDFACS Appl Mater Interfaces
January 2025
School of Precision Instrument and Optoelectronics Engineering, Tianjin University, 92 Weijin Road, Tianjin 300072, China.
Traditional tactile sensors are single-function, and it is difficult to meet the needs of applications in complex environments. This paper describes the development and applications of flexible tactile sensors with cilia based on magnetoelectric composites made of neodymium iron boron (NdFeB) microparticles with a silver (Ag) nanoshell in polydimethylsiloxane (PDMS). These sensors adopt the inherent magnetism of NdFeB microparticles and the excellent conductivity of the Ag coating.
View Article and Find Full Text PDFJ Coll Physicians Surg Pak
January 2025
Department of Chemical Pathology and Endocrinology, Armed Forces Institute of Pathology (AFIP), Rawalpindi, Pakistan.
Objective: To evaluate the role of serum thyroglobulin (TG) as a biochemical marker for differential diagnosis of common aetiologies of hyperthyroidism.
Study Design: Comparative cross-sectional study. Place and Duration of the Study: Department of Chemical Pathology and Endocrinology, Armed Forces Institute of Pathology (AFIP), Rawalpindi, Pakistan, from October 2023 to March 2024.
J Nanobiotechnology
January 2025
School of Medicine, Shanghai University, Shanghai, 200444, China.
Biochips are widely applied to manipulate the geometrical morphology of stem cells in recent years. Patterned antenna-like pseudopodia are also probed to explore the influence of pseudopodia formation on gene delivery and expression on biochips. However, how the antenna-like pseudopodia affect gene transfection is unsettled and the underlying trafficking mechanism of exogenous genes in engineered single cells is not announced.
View Article and Find Full Text PDFBMC Oral Health
January 2025
Faculty of Dentistry, Department of Endodontics, Ondokuz Mayis University, Samsun, Kurupelit, 55139, Turkey.
Background: The aim was to evaluate the stresses in teeth, with external root resorption (ERR) restored with different materials using finite element analysis (FEA).
Methods: In this study, a Micro-CT scan was conducted on a prepared maxillary central tooth. DICOM-compatible images obtained from the sections were converted into stereolithography format using Ctan software.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!