Hand-arm symptoms related to impact and nonimpact hand-held power tools.

Int Arch Occup Environ Health

Department of Ergonomics, National Institute for Working Life, Solna, Sweden.

Published: August 1997

Hand and arm symptoms among workers using impact and non-impact hand-held power tools were investigated in a cross-sectional study and a 5-year follow-up study. The study population consisted of concrete workers (n = 103), truck assemblers (n = 234), electricians (n = 101), platers (n = 140) and lumberjacks (n = 102). Of the original 680 subjects, we followed up 312 after 5 years. A questionnaire concerning ongoing hand and arm symptoms, daily exposure to hand-held power tools, type of tool used, and individual factors was administered. More workers using low-frequency impact tools than workers using non-impact tools reported symptoms in the elbows and shoulders. Elbow symptoms were accentuated in the cross-sectional study, while shoulder symptoms were accentuated in the follow-up study. Wrist symptoms were reported by more of those working with high-frequency impact tools than of those using only non-impact tools when the analyses were controlled for age, years in the occupation and smoking habits. A possible explanation of the results found in this study is that low-frequency impact vibration is transmitted to the upper arm, and thus the elbow and shoulder are at risk, while high-frequency impact vibration is attenuated in the hand and wrist and may predominantly cause symptoms there.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s004200050148DOI Listing

Publication Analysis

Top Keywords

hand-held power
12
power tools
12
hand arm
8
arm symptoms
8
cross-sectional study
8
follow-up study
8
low-frequency impact
8
impact tools
8
non-impact tools
8
symptoms accentuated
8

Similar Publications

In carpal tunnel syndrome (CTS), pain and sensory disturbance are the main symptoms, but thumb palmar abduction (TPA) paralysis cannot be ignored as a concurrent symptom. The reliable quantitative measurement of TPA power was not established. The purpose of this study was to report on the reliability of TPA strength measurements by the hand-held dynamometry (HHD) in large samples of CTS and its superiority over other tests, including grip, pinch powers, TPA angles and manual muscle testing, in terms of clinical progress indicators.

View Article and Find Full Text PDF

Magnetoactive elastomer-based dynamic urethral support device for stress urinary incontinence.

Acta Biomater

January 2025

Texas A&M University, Department of Biomedical Engineering, College Station, TX, United States; Texas A&M University, Department of Materials Science and Engineering, College Station, TX, United States. Electronic address:

Stress urinary incontinence (SUI) is the involuntary leakage of urine in response to increased intra-abdominal pressure during episodes of exertion. A common treatment method for SUI is sling implantation underneath the urethra to provide support. Most current sling procedures, however, cannot adjust urethral tension postoperatively.

View Article and Find Full Text PDF

A hand-held in-situ nucleic acid detection device based on dual-function GHz acoustofluidic resonator.

Biosens Bioelectron

January 2025

State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin, 300072, China. Electronic address:

Microfluidic-based nucleic acid testing (NAT) has been proven as an alternative approach for in-situ and rapid NA detection. However, these on-chip methods still require complex peripherals, which contradict the purpose of point-of-care (POC) applications. One of the major challenges is the integration of NA purification and amplification in a miniaturized setup with high mass and heat transfer efficiency.

View Article and Find Full Text PDF

Introduction: The aim of this study was to determine the short- and long-term effects of foam rolling (FR) on the pressure pain threshold and the range of motion of the lumbar spine in healthy subjects.

Methods: 43 healthy subjects without back problems were randomly assigned to an experimental group (EG) or a control group (CG). The subjects in the EG underwent a 4-week FR program (12 sessions).

View Article and Find Full Text PDF

Exhaled breath analysis: A promising triage test for tuberculosis in young children.

Tuberculosis (Edinb)

December 2024

Oxford Vaccine Group, Department of Paediatrics, University of Oxford, Oxford, UK; Division of Infectious Diseases, Boston Children's Hospital, Boston, MA, USA; Department of Pediatrics, Harvard Medical School, Boston, MA, USA. Electronic address:

The diagnosis of paediatric pulmonary tuberculosis is difficult, especially in young infants who cannot expectorate sputum spontaneously. Breath testing has shown promise in diagnosing respiratory tract infections, but data on paediatric tuberculosis are limited. We performed a prospective cross-sectional study in Kenya in children younger than five years with symptoms of tuberculosis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!