The purpose of this study was to characterize the cell types (using immunohistochemistry) and cytokine expression (using in situ hybridization) of tissues surrounding well fixed and loose cemented prostheses undergoing revision. Clinical and radiographic data were gathered prospectively for a series of cemented total joint replacements undergoing revision. Three groups were identified: (1) loose implants with osteolysis (10 specimens), (2) loose implants without osteolysis (11 specimens), and (3) well fixed implants (7 specimens). At surgery, a specimen was harvested from the bone cement interface. Immunohistochemical staining was performed using monoclonal antibodies to identify macrophages and lymphocyte subgroups. Human antisense probes were selected to identify the mRNA for specific cytokines using in situ hybridization. The percentage of positively staining cells was determined for each antibody or probe using a grid counting technique. Tissues from loose cemented prostheses with osteolysis contained significantly greater numbers of macrophages and T lymphocytes compared with tissues from loose and well fixed cemented prostheses without osteolysis. The number of interleukin-1 and interleukin-6 positive cells was highest in specimens with osteolysis and lowest in specimens from well fixed prostheses. These cytokines modulate the growth and differentiation of cells in the immune system and the monocyte and macrophage system and mediate the remodeling of bone and mesenchymal tissues. Specific cell populations and cytokine profiles appear to be involved in periprosthetic osteolysis; this information may be useful in planning strategies for prevention and treatment.

Download full-text PDF

Source
http://dx.doi.org/10.1097/00003086-199704000-00017DOI Listing

Publication Analysis

Top Keywords

well fixed
16
cemented prostheses
12
situ hybridization
8
loose cemented
8
undergoing revision
8
loose implants
8
implants osteolysis
8
osteolysis specimens
8
specimens well
8
tissues loose
8

Similar Publications

Cortical windows for implant and cement removal during revision total elbow arthroplasty.

JSES Int

November 2024

Division of Hand and Upper-Extremity Surgery, Department of Orthopaedic Surgery, Geisinger Commonwealth School of Medicine, Geisinger MSKI, Danville, PA, USA.

Background: Revision total elbow arthroplasty (rTEA) remains a technically challenging procedure with potential for substantial morbidity. Cases involving excessively long cement mantles, removal of well-fixed implants or infected revisions requiring complete cement removal introduce additional technical challenges. Our purpose was to describe the outcomes, results, and complications associated with the use of cortical windows in rTEA.

View Article and Find Full Text PDF

The meniscus effect in cell culture vessels limits the observable areas with phase contrast microscopy. For meniscus effect compensation in microtiter plates (MTPs), we present a method using an LCD to replace the fixed condenser annulus, which enables adaptive annulus shifting based on image analysis. This approach led to an increase in phase contrast area by a factor of 8.

View Article and Find Full Text PDF

Background: Anatomically formed healing abutments were suggested in literature to address many of the issues associated with immediate posterior implant insertion such as large extraction sockets that are extremely hard to seal without reflecting the mucoperiosteal flap, extraction sockets anatomy that are not suitable for regular healing abutment placement, and potentially high occlusal stresses when planning a temporary implant supported prothesis to improve the conditioning of supra implant tissue architecture and the emergence profile of the implant supported restorations.

Purpose: To clinically evaluate the peri-implant soft tissue profile of single posterior implant retained restorations and to assess patient related outcomes of the implant restorations that were conditioned immediately by CAD-CAM socket sealing abutments (SSA) versus those conditioned by Titanium (Ti) standard healing abutments (SHA).

Methods: Twenty participants received twenty-two single maxillary immediate implants after flapless minimally invasive tooth extraction and 3D guided implant placement in the posterior area (premolar and molar) and allocated randomly into two groups (n = 11), the intervention group: patients received PEEK SSA and the control group: the patients received Ti SHA.

View Article and Find Full Text PDF

Compositional data are multivariate data made up of components that sum to a fixed value. Often the data are presented as proportions of a whole, where the value of each component is constrained to be between 0 and 1 and the sum of the components is 1. There are many applications in psychology and other disciplines that yield compositional data sets including Morris water maze experiments, psychological well-being scores, analysis of daily physical activity times, and components of household expenditures.

View Article and Find Full Text PDF

Informing Risk Hotspots and Critical Mitigations for Rainstorms Using Machine Learning: Evidence from 268 Chinese Cities.

Environ Sci Technol

January 2025

State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing 210023, China.

Climate change is exacerbating rainstorms, increasing the risk of flooding and threatening urban sustainability, which could undermine climate action. Here, we propose a machine learning-based framework to assess heterogeneous risks and identify critical mitigation measures for rainstorms across 268 Chinese cities. Nighttime light serves as a proxy for urban functionality, and meteorological, socio-economic, and infrastructural factors are incorporated to uncover underlying impact mechanisms.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!