The purpose of this study was to comparatively evaluate the quality of SPECT images for the mapping of rCBF using three tracers, 123I-IMP, 99mTc-HMPAO and 99mTc-ECD. We performed three SPECT studies on seven patients with various cerebral diseases under the same conditions. An effect of Lassen's correction on SPECT images obtained by HMPAO was also evaluated. The same irregular regions of interest were placed on the four transaxial SPECT images. To quantitatively evaluate the pattern of tracer uptake and image contrast, the uptake ratio, regional count/mean count of the cerebrum, and its coefficient variations (CV) were defined, respectively. The order of the value of CV was HMPAO with correction > IMP > ECD > HMPAO without correction. HMPAO with correction showed the best image contrast, but HMPAO without correction was the worst. Uptake ratios of ECD and HMPAO with correction were decreased in the brain stem and thalamus in comparison with those of IMP. Both uptake ratios of ECD and HMPAO without correction were increased in the occipital cortex. IMP provides high quality SPECT images. Images obtained by HMPAO should be modified by Lassen's correction to increase image contrast. ECD or HMPAO should not be used to evaluate patients with spinocerebellar degeneration.

Download full-text PDF

Source

Publication Analysis

Top Keywords

hmpao correction
24
spect images
20
ecd hmpao
16
quality spect
12
image contrast
12
hmpao
9
123i-imp 99mtc-hmpao
8
correction
8
lassen's correction
8
images hmpao
8

Similar Publications

Background: Rapid eye movement sleep behavior disorder (RBD) is an established prodrome and symptom of synucleinopathies. The pathophysiology of this disorder has been well studied but there is a lack of functional imaging data to illustrate the dysfunction in vivo.

Objectives: We aimed to investigate the functional changes of RBD, by performing ictal REM sleep SPECT, comparing subjects with Parkinson's Disease (PD) and evidence of RBD to subjects with PD and no RBD.

View Article and Find Full Text PDF

The differential diagnosis of MSA-P and PSP-P remains a difficult issue in clinical practice due to their overlapping clinical manifestation and the lack of tools enabling a definite diagnosis ante-mortem. This paper describes the usefulness of SPECT HMPAO in MSA-P and PSP-P differentiation through the analysis of cerebellar perfusion of small ROIs. Thirty-one patients were included in the study—20 with MSA-P and 11 with PSP-P; the analysis performed indicated that the most significant difference in perfusion was observed in the anterior quadrangular lobule (H IV and V) on the left side (p < 0.

View Article and Find Full Text PDF

Imaging with [Tc]HMPAO - a novel perspective: investigation of [Tc]HMPAO leg muscle uptake in metabolic diseases.

Acta Radiol

January 2023

Department of Medical Imaging, Division of Nuclear Medicine and Translational Imaging, Faculty of Medicine, 443158University of Debrecen, Debrecen, Hungary.

Background: Sensitive imaging modalities in the diagnosis of microcircular complications of the lower extremities induced by metabolic diseases are becoming a focus of interest.

Purpose: To investigate the [Tc]HMPAO uptake of the legs in type 2 diabetes mellitus (T2DM) and obesity, and to search for associations with clinical parameters and nerve conducting studies.

Material And Methods: A total of 57 patients with controlled T2DM and 46 obese participants without DM were enrolled in the study.

View Article and Find Full Text PDF

Purpose: Ictal brain perfusion SPECT with the tracer 99mTc-HMPAO or 99mTc-ECD is widely used for identification of the epileptic seizure onset zone (SOZ) in presurgical evaluation if standard pointers are uncertain or inconsistent. For both tracers, there are theoretical arguments to favor it over the other for this task. The aim of this study was to compare the performance of ictal brain perfusion SPECT between 99mTc-HMPAO and 99mTc-ECD in a rather large patient sample.

View Article and Find Full Text PDF

Automatic attenuation map estimation from SPECT data only for brain perfusion scans using convolutional neural networks.

Phys Med Biol

March 2021

Section Biomedical Imaging, Department of Radiation, Science and Technology, Delft University of Technology, Delft, The Netherlands.

In clinical brain SPECT, correction for photon attenuation in the patient is essential to obtain images which provide quantitative information on the regional activity concentration per unit volume (kBq.[Formula: see text]). This correction generally requires an attenuation map ([Formula: see text] map) denoting the attenuation coefficient at each voxel which is often derived from a CT or MRI scan.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!