Myocardial contractile pathways which are not aligned strictly parallel to the heart's epicardial surface, give rise to forces which also act in the ventricular dilating direction. We developed a method which allows us to assess any fibre orientation in the three-dimensional myocardial weave. Decollagenized hearts were prepared by peeling-off fibre strands, following their main fibre orientation down to near the endocardium. In the subepicardium the strands followed a course more or less parallel to the epicardium, whereas from the mid-wall on they tended to dive progressively deeper into the wall. The preparation displays more or less rugged surfaces rather than smooth layers. The grooves and crests on the exposed surfaces were sequentially digitized by two methods: (1) Using a magnet tablet (3 Draw Digitizer System, Polhemus, Cochester VTO 5446, USA) on a dilated pig heart we manually followed the crests using a stylus, handling each groove and crest as an individual contractile pathway. (2) A constricted cow heart was digitized using a contact-free optical system (opto TOP, Dr. Breuckmann, Meersburg, Germany), which is based on the principle of imaging triangulation. Using specially developed software the inclination angles of selected crests and grooves with respect to the epicardial surface were calculated. The two digitizing methods yield comparable results. We found a depth- and side-specific weave component inclined to the epi-endocardial direction. This oblique netting component was more pronounced in the inner 1/3 of the wall than in the subepicardium. The inclination angle probably increases with increasing wall thickness during the ejection period. Manual digitizing is an easy and fast method which delivers consistent results comparable with those obtained by the cumbersome high resolution optical method. The rationales for the assessment of transmural fibre inclination are (1) the putative existence of dilating forces inherent in the myocardial weave and (2) the possible overproportional increase in the oblique transmural weave component during myocardial hypertrophy, which would entail a reduction in efficiency of ventricular performance in terms of haemodynamic work.

Download full-text PDF

Source

Publication Analysis

Top Keywords

inclination angle
8
wall thickness
8
epicardial surface
8
fibre orientation
8
myocardial weave
8
weave component
8
heart's fibre
4
fibre alignment
4
alignment assessed
4
assessed comparing
4

Similar Publications

Joint gravitational-wave and γ-ray burst (GRB) observations are among the best prospects for standard siren cosmology. However, the strong selection effect for the coincident GRB detection, which is possible only for sources with small inclination angles, induces a systematic uncertainty that is currently not accounted for. We show that this severe source of bias can be removed by inferring the a priori unknown electromagnetic detection probability directly from multimessenger data.

View Article and Find Full Text PDF

Objective: The aim of this study was to evaluate whether the locking femoral neck plate (LFNP) can be an alternative fixation method to the cannulated screws with a medial buttress plate. For this purpose, we compared biomechanically the LFNP and cannulated screws with or without a medial buttress plate in Pauwels type 3 femoral neck fractures.

Methods: A vertical fracture model was created at an 80-degree angle to the femoral neck in 28 synthetic bone models.

View Article and Find Full Text PDF

Background: Periprosthetic hip dislocation after total hip arthroplasty is a devastating postoperative complication. It is often associated with suboptimal orientation of the acetabular component, characterized by the acetabular abduction and anteversion angles obtained from anteroposterior pelvic radiographs. We introduce a novel automated web tool to streamline the subjective and lengthy process of this manual measurement and compare it to manual human measurements.

View Article and Find Full Text PDF

Mapping the myomagnetic field of a straight and easily accessible muscle after electrical stimulation using triaxial optically pumped magnetometers (OPMs) to assess potential benefits for magnetomyography (MMG). Approach: Six triaxial OPMs were arranged in two rows with three sensors each along the abductor digiti minimi (ADM) muscle. The upper row of sensors was inclined by 45° with respect to the lower row and all sensors were aligned closely to the skin surface without direct contact.

View Article and Find Full Text PDF

Background And Objectives: Currently, there remains a paucity of research on the deformation and valve function of transcatheter heart valves (THV) in patients with aortic regurgitation (AR) following transcatheter aortic valve replacement (TAVR). This study aimed to thoroughly explore the correlation between THV deformation and postoperative hemodynamics in these patients.

Methods: In this study, we assessed 39 AR patients treated with the J-Valve THV system during TAVR.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!