Objective: The purpose of this study was to describe the variable anatomy of mesenteric veins on axial CT images and on volume-rendered CT venograms that use maximum intensity projection and shaded-surface display.

Subjects And Methods: Fifty-seven patients undergoing helical CT of the pancreas were included in the study. The mesenteric venous system was analyzed in 54 patients. Three patients were excluded because the helical CT data were unsatisfactory.

Results: On helical CT with maximum intensity projection and shaded-surface display, the superior mesenteric vein (SMV) was seen as a single trunk of variable length in 40 patients. In seven other patients, two mesenteric trunks merged separately with the splenic vein. In the remaining seven patients, the SMV was occluded by tumor. The inferior mesenteric vein drained into the splenic vein in 28 patients (56%), into the SMV in 14 patients (26%), and into the splenomesenteric angle in nine patients (18%).

Conclusion: Both axial and volume-rendered CT venograms accurately reveal the variable mesenteric venous anatomy. CT venograms may replace conventional angiography in presurgical planning.

Download full-text PDF

Source
http://dx.doi.org/10.2214/ajr.168.5.9129413DOI Listing

Publication Analysis

Top Keywords

patients
9
mesenteric veins
8
volume-rendered venograms
8
maximum intensity
8
intensity projection
8
projection shaded-surface
8
mesenteric venous
8
mesenteric vein
8
splenic vein
8
mesenteric
7

Similar Publications

Importance: States have implemented multiple policies likely to influence opioid prescribing; few national general population studies examine those policies' effects on per-capita opioid morphine milligram equivalents (MME) dispensed.

Objective: To examine state policies' effects on opioids per-capita MMEs dispensed at retail pharmacies.

Design: A longitudinal study of associations between MME per capita and implementation of policy interventions at different times across states.

View Article and Find Full Text PDF

Deep Equilibrium Unfolding Learning for Noise Estimation and Removal in Optical Molecular Imaging.

Comput Med Imaging Graph

January 2025

CAS Key Laboratory of Molecular Imaging, Institute of Automation, Chinese Academy of Sciences, Beijing 100190, China; School of Artificial Intelligence, University of Chinese Academy of Sciences, Beijing 100049, China; National Key Laboratory of Kidney Diseases, Beijing 100853, China. Electronic address:

In clinical optical molecular imaging, the need for real-time high frame rates and low excitation doses to ensure patient safety inherently increases susceptibility to detection noise. Faced with the challenge of image degradation caused by severe noise, image denoising is essential for mitigating the trade-off between acquisition cost and image quality. However, prevailing deep learning methods exhibit uncontrollable and suboptimal performance with limited interpretability, primarily due to neglecting underlying physical model and frequency information.

View Article and Find Full Text PDF

Feasibility of very low iodine dose aortoiliac CT angiography using dual-source photon-counting detector CT.

Eur J Radiol

January 2025

Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany; Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, USA. Electronic address:

Purpose: To evaluate the feasibility of aortoiliac CT-Angiography (CTA) using dual-source photon-counting detector (PCD)-CT with minimal iodine dose.

Methods: This IRB-approved, single-center prospective study enrolled patients with indications for aortoiliac CTA from December 2022 to March 2023. All scans were performed using a first-generation dual-source PCD-CT.

View Article and Find Full Text PDF

Feasibility of on-site CT-FFR analysis on cardiac photon-counting CT in evaluation of hemodynamically significant stenosis in comparison to invasive catheter angiography.

Eur J Radiol

January 2025

Department of Radiology and Nuclear Medicine, University Medical Center Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany. Electronic address:

Objectives: Coronary CT angiography (CCTA) is an excellent tool in ruling out coronary artery disease (CAD) but tends to overestimate especially highly calcified plaques. To reduce diagnostic invasive catheter angiographies (ICA), current guidelines recommend CT-FFR to determine the hemodynamic significance of coronary artery stenosis. Photon-Counting Detector CT (PCCT) revolutionized CCTA and may improve CT-FFR analysis in guiding patients.

View Article and Find Full Text PDF

[F]FDG PET/CT versus Dynamic Contrast-Enhanced CT for the diagnosis of solitary pulmonary Nodule: A Head-to-Head comparative Meta-Analysis.

Eur J Radiol

January 2025

Third Hospital of Shanxi Medical University, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Tongji Shanxi Hospital, Taiyuan, 030032, China; Department of Pulmonary and Critical Care Medicine, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Third Hospital of Shanxi Medical University, Tongji Shanxi Hospital, Taiyuan, 030032, China; Department of Pulmonary and Critical Care Medicine, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China. Electronic address:

Purpose: This head-to-head comparative meta-analysis aimed to evaluate the comparative diagnostic efficacy of [F]FDG PET/CT and dynamic contrast-enhanced CT(DCE-CT) for the differentiation between malignant and benign pulmonary nodules.

Methods: An extensive search was conducted in the PubMed, Embase, and Web of Science to identify available publications up to March 23, 2024. Studies were included if they evaluated the diagnostic efficacy of [F]FDG PET/CT and DCE-CT for the characterization of pulmonary nodules.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!