We report the case of a symptomatic adult with an occluded persistent duct with a transcatheter proceeding using a Rashkind prosthesis. After a month of follow up the color-coded Doppler-flow echocardiogram did not show residual shunt, posteriorly the patient's symptoms disappeared and the left ventricular dimensions were reduced. At the thirteen month of follow-up, the patient had an accident while working, falling down from a scaffold. Afterwards, a ductal jet was observed in the echocardiogram with an increased size of the left ventricle, symptoms also appeared. A cardiac catheterism was then performed showing a pulmonary/systemic flow rate of 2 and a 3 mm flow jet at the superior border of the prosthesis. A second prosthesis was implanted with no residual shunts.