The accuracy of measurements of mitral valve orifice area (MVA) from three-dimensional echocardiographic (3DE) image data sets obtained by a transthoracic or transesophageal rotational imaging probe was studied in 15 patients with native mitral stenosis. The smallest MVA was identified from a set of eight parallel short-axis cut planes of the mitral valve between the anulus and the tips of leaflets (paraplane echocardiography) and measured by planimetry. In addition, MVA was measured from the two-dimensional short-axis view (2DE). Values of MVA measured by 3DE and 2DE were compared with those calculated from Doppler pressure half-time (PHT) as a gold standard. Observer variabilities were studied for 3DE. MVA measured from PHT ranged between 0.55 and 3.19 cm2 (mean +/- SD 1.57 +/- 0.73 cm2), from 3DE between 0.83 and 3.23 cm2 (mean +/- SD 1.55 +/- 0.67 cm2), and from 2DE between 1.27 and 4.08 cm2 (mean +/- SD 1.9 +/- 0.7 cm2). The variability of intraobserver and interobserver measurements for 3DE measurements was not significantly different (p = 0.79 and p = 0.68, respectively); for interobserver variability, standard error of the estimate = 0.25. There was excellent correlation, close limits of agreement (mean difference +/- 2 SD), and nonsignificant differences between 3DE and PHT for MVA measurements (r = 0.98 [0.02 +/- 0.3] and p = 0.6), respectively. There was moderate correlation, wider limits of agreement, and significant difference between 2DE and PHT for MVA measurements (r = 0.89 [0.32 +/- 0.66] and p = 0.002), respectively. This may be related to the difficulties in visualization of the smallest orifice in precordial short-axis views. This study suggests that three-dimensional image data sets, by providing the possibility of "computer slicing" to generate equidistant parallel cross sections of the mitral valve independently from physically dictated ultrasonic windows, allow accurate and reproducible measurement of the MVA.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0894-7317(97)70085-3DOI Listing

Publication Analysis

Top Keywords

mitral valve
16
mva measured
12
cm2 +/-
12
+/-
9
mitral stenosis
8
mva
8
image data
8
data sets
8
limits agreement
8
agreement difference
8

Similar Publications

Characterization of LTBP2 mutation causing mitral valve prolapse.

Eur Heart J Open

January 2025

Department of Medicine, Cardiovascular Precision Medicine Center, Hadassah Hebrew University Medical Center, P.O. Box 12000, 9112001 Jerusalem, Israel.

Aims: Mitral valve prolapse (MVP) is a common valvular disorder associated with significant morbidity and mortality, with a strong genetic basis. This study aimed to identify a mutation in a family with MVP and to characterize the valve phenotype in LTBP2 knockout (KO) mice.

Methods And Results: Exome sequencing and segregation analysis were performed on a large family with MVP.

View Article and Find Full Text PDF

Introduction: The severity of mitral stenosis (MS) is commonly assessed using mitral valve area (MVA) measured with transthoracic echocardiography (TTE). The dimensionless index (DI) of mitral valve (MV) was recently studied in degenerative MS. We evaluated DI MV in rheumatic MS and studied its relationship with clinical outcomes.

View Article and Find Full Text PDF

Infectious intracranial aneurysms (IIAs) are rare lesions with fragile arterial walls located within the aneurysms, carrying a high risk of rupture. Standard management often involves antibiotic therapy and parent artery occlusion; however, the latter carries a significant risk of cerebral infarction. This report presents a case of an unruptured IIA following cerebral infarction, successfully treated with coil embolization while preserving the parent artery.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!