Clinical evaluation of a thin bipolar pacing lead.

Pacing Clin Electrophysiol

Medical Department A, University School of Medicine, Bergen, Norway.

Published: March 1997

AI Article Synopsis

Article Abstract

The main disadvantages of bipolar pacing leads have traditionally been related to their relative thickness and stiffness compared to unipolar leads. In a new "drawn filled tube" plus "coated wire" technology, each conductor strand is composed of MP35N tubing filled with silver core and coated with a thin ETFE polymer insulation material. This and parallel winding of single anode and cathode conductors into a single bifilar coil resulted in a bipolar lead (ThinLine, Intermedics) with a body diameter and flexibility similar to unipolar leads. The lead is tined, polyurethane, with the cathode and the anode made of iridium-oxide-coated titanium (IROX). The slotted 8-mm2 cathode tip is coated with polyethylene glycol, a blood soluble material. We present the clinical evaluation results from four pacemaker clinics, where 47 leads (23 atrial-J model 432-04 and 24 ventricular model 430-10) were implanted in 25 patients and followed for up to 2 years. The lead handling characteristics were found to be very satisfactory. Electrical parameters of the leads were measured at implant and noninvasively on postoperative days 1, 2, 21, 42, and months 3, 6, 12, and 24. Mean chronic pulse width thresholds at 2.5 V were 0.14 +/- 0.05 ms in the atrium and 0.10 +/- 0.02 ms in the ventricle, pacing impedances 443 +/- 104 omega and 520 +/- 241 omega, while median electrogram amplitudes were > or = 3.5 mV and > or = 7 mV, respectively. Pacing impedances and thresholds were found to be slightly but statistically significantly higher in unipolar than in bipolar configuration--the findings are explainable by the lead construction. One of 47 leads failed 3 weeks after implant; the conductors were short circuited due to an error during the manufacturing process. We conclude that the new lead thus far has demonstrated appropriate mechanical and electrical characteristics.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1540-8159.1997.tb03882.xDOI Listing

Publication Analysis

Top Keywords

clinical evaluation
8
bipolar pacing
8
unipolar leads
8
pacing impedances
8
lead
6
leads
6
evaluation thin
4
bipolar
4
thin bipolar
4
pacing
4

Similar Publications

Objective: This study investigates the relationship between the albumin-to-creatinine ratio and diabetic retinopathy (DR) in US adults using NHANES data from 2009 to 2016. This study assesses the predictive efficacy of the urinary serum albumin-to-creatinine ratio (UACR/SACR Ratio) against traditional biomarkers such as the serum albumin-to-creatinine ratio (SACR) and urinary albumin-to-creatinine ratio (UACR) for evaluating DR risk. Additionally, the study explores the potential of these biomarkers, both individually and in combination with HbA1c, for early detection and risk stratification of DR.

View Article and Find Full Text PDF

Introduction: Although there are numerous options for epilepsy treatment, its effective control continues unsatisfactory. Thus, search for alternative therapeutic options to improve the efficacy/safety binomial of drugs becomes very attractive to investigate. In this context, intranasal administration of antiseizure drugs formulated on state-of-the-art nanosystems can be a promising strategy.

View Article and Find Full Text PDF

A Unified Approach to Health Data Exchange: A Report From the US DHHS.

JAMA

January 2025

Assistant Secretary for Technology Policy/Office of the National Coordinator for Health IT, Washington, DC.

Importance: Health information technology, such as electronic health records (EHRs), has been widely adopted, yet accessing and exchanging data in the fragmented US health care system remains challenging. To unlock the potential of EHR data to improve patient health, public health, and health care, it is essential to streamline the exchange of health data. As leaders across the US Department of Health and Human Services (DHHS), we describe how DHHS has implemented fundamental building blocks to achieve this vision.

View Article and Find Full Text PDF

Introduction: This prospective, single-arm pharmacodynamic study assessed the effect of colchicine (COLC) [Strides Pharma UK Ltd, Watford, Hertfordshire, England] 0.5 mg administered orally once daily for 14 days on platelet reactivity with respect to aspirin reaction units (ARUs) and P2Y reaction units (PRUs).

Methods: Twenty-two patients with stable coronary artery disease (CAD) on dual antiplatelet therapy (DAPT) with daily maintenance aspirin and clopidogrel were recruited.

View Article and Find Full Text PDF

Purpose: To assess the efficacy and safety of PreserFlo MicroShunt (PMS) combined with mitomycin C in patients with medically treated primary open-angle glaucoma (POAG).

Study Design: A retrospective observational study.

Methods: The study examined 83 eyes from 83 patients with medically treated glaucoma surgery naive POAG.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!