Influence of picrotoxin and strychnine on the spectral sensitivity of the turtle ERG b- and d-wave: I. Dark adaptation.

Acta Physiol Scand

Department of Physiology, Medical Faculty-Sofia, Bulgaria.

Published: March 1997

The ERG ON- (b-wave) and OFF-response (d-wave) to differently coloured stimuli was studied using a wide range of stimulus intensities in dark adapted turtle retina. The intensity-response curve of the b-wave showed saturation but that of the d-wave, decline in the high-intensity stimulus range. The curves of the relative spectral sensitivity of the ERG ON- and OFF-response were similar and showed a maximum in the longwave part of the spectrum. GABAergic blockade by 50 mumol L-1 picrotoxin caused an increase of the sensitivity, contrast sensitivity and the amplitude range of both ON- and OFF-responses without narrowing of the response dynamic range. In the range of lower stimulus intensities the ON-responses to blue stimuli and the OFF-responses to red stimuli were affected to a greater extent. An increased ERG b- and d-wave sensitivity was also observed during glycinergic blockade by 50 mumol L-1 strychnine. In the low intensity stimulus range the effect was maximal on the ON-response to blue stimuli and on the OFF-responses to 570 nm stimuli. It was concluded that the GABA- and glycinergic systems in the retina equalize rather than make different the relative spectral sensitivities of the ON- and OFF-responses.

Download full-text PDF

Source
http://dx.doi.org/10.1046/j.1365-201X.1997.97359000.xDOI Listing

Publication Analysis

Top Keywords

spectral sensitivity
8
erg d-wave
8
erg on-
8
stimulus intensities
8
stimulus range
8
relative spectral
8
blockade mumol
8
mumol l-1
8
on- off-responses
8
blue stimuli
8

Similar Publications

Nanoparticles-Based Optical Chemosensors for Lead Acetate Sensing in Water: ZnO, ZnCeO, and ZnNdO.

J Fluoresc

January 2025

Materials Science Lab (1), Physics Department, Faculty of Science, Cairo University, Giza, Egypt.

This study reports the synthesis, characterization, and optical properties of ZnO, ZnCeO, and ZnNdO nanoparticles and their interactions with lead acetate solutions. X-ray diffraction (XRD) confirmed that the nanoparticles were synthesized in a single-phase hexagonal structure, with crystallite sizes of 12.48 nm, 50.

View Article and Find Full Text PDF

Off-axis integrated cavity output spectroscopy (OA-ICOS) allows the laser to be reflected multiple times inside the cavity, increasing the effective absorption path length and thus improving sensitivity. However, OA-ICOS systems are affected by various types of noise, and traditional filtering methods offer low processing efficiency and perform limited feature extraction. Deep learning models enable us to extract important features from large-scale, complex spectral data and analyze them efficiently and accurately.

View Article and Find Full Text PDF

Photon-counting mammography is an emerging modality that allows for spectral imaging and provides a differentiation of material compositions. The development of photon-counting mammography-specific contrast agents has yet to be explored. In this study, the contrast, sensitivity, and organ dose between silver sulfide nanoparticles (AgS-NPs) and a clinically approved iodinated agent (iopamidol) were investigated using a contrast-embedded gradient ramp phantom and a prototype scanner.

View Article and Find Full Text PDF

Integrating hyperspectrograms with class modeling techniques for the construction of an effective expert system: Quality control of pharmaceutical tablets based on near-infrared hyperspectral imaging.

J Pharm Biomed Anal

January 2025

Institute of Chemistry, University of Silesia in Katowice, 9 Szkolna Street, Katowice 40-006, Poland; SPIN-Lab Centre for Microscopic Studies on Matter, University of Silesia in Katowice, 75 Pulku Piechoty Street 1, Chorzow 41-500, Poland. Electronic address:

Near-infrared hyperspectral imaging (NIR-HSI) integrated with expert systems can support the monitoring of active pharmaceutical ingredients (APIs) and provide effective quality control of tablet formulations. However, existing quality control methods usually test a limited number of variability sources affecting the final product. This study examines the potential of NIR-HSI (in the spectral range of 935.

View Article and Find Full Text PDF

New applications such as the Internet of Things, autonomous driving, Industry X.0 and many more will transmit sensitive information via fibers and over the air with envisioned data rates beyond terabits per second. Therefore, the encryption has to be simple, fast and spectrally efficient, so that the power consumption and latency are low and the scarce bandwidth is not wasted.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!