Cylindrical plugs of polymerized Simplex-P bone cement with and without barium sulfate were implanted in the rabbit tibial metaphysis. Titanium was used as control material. The animals were observed for 4--4.5 months. Histological analysis showed that all titanium implants were healed into the bone with a direct bone-implant contact, which was also true for about 60% of the cement implants. The remaining cement implants were encapsulated by connective tissue, probably due to biomechanical factors. It was not possible in this study to show a difference in the tissue reaction to bone cement containing barium sulfate and bone cement free from barium sulfate.

Download full-text PDF

Source
http://dx.doi.org/10.1007/BF00415342DOI Listing

Publication Analysis

Top Keywords

bone cement
16
barium sulfate
16
cement barium
12
cement implants
8
cement
6
bone
5
[tissue compatibility
4
compatibility bone
4
barium
4
sulfate
4

Similar Publications

Objective: This study aims to elucidate the impact of varying tourniquet application timings on postoperative pain and the bone cement interface following TKA.

Method: Patients who underwent TKA in our department between March 2021 and July 2023 were included in this study. They were randomly assigned to three groups: Group 1 used tourniquets throughout the operation, Group 2 applied tourniquets before the osteotomy, and Group 3 applied tourniquets after completing the osteotomy.

View Article and Find Full Text PDF

Anaerobic Adhesive Effect on the Counter-Torque of Zirconia Implant Abutment Screws: In Vitro Study.

Clin Implant Dent Relat Res

February 2025

Department of Restorative Dentistry, Faculty of Dentistry, Universidade Federal de Minas Gerais, Belo Horizonte, Brazil.

Introduction: Implantology has become a primary solution for tooth loss due to excellent osseointegration and high long-term success rates. However, complications such as abutment screw loosening, especially in implant-supported single crowns, compromise prosthesis longevity. Anaerobic adhesives (AAs) have shown promise in mechanical fields for preventing screw loosening, but their effectiveness in dental implants, particularly zirconia, remains uncertain.

View Article and Find Full Text PDF

Background: Limitations to using the knee as donor cartilage include cartilage thickness mismatch and donor site morbidity. Using the radial head as donor autograft for capitellar lesions may allow for local graft harvest without distant donor site morbidity. The purpose of this study is to demonstrate the feasibility of performing local osteochondral autograft transfer from the nonarticular cartilaginous rim of the radial head to the capitellum.

View Article and Find Full Text PDF

Introduction: Arterial vascular occlusion is a rare complication of dermal filler injection. This case report describes the successful use of hyperbaric oxygen therapy in a patient with vascular occlusion after a permanent dermal filler was injected.

Case Report: A 51-year-old woman underwent an injection of non-resorbable polymethylmethacrylate microspheres into her nasolabial folds.

View Article and Find Full Text PDF

Background: Prone lateral spinal surgery for simultaneous lateral and posterior approaches has recently been proposed to facilitate surgical room efficiency. The purpose of this study is to evaluate the feasibility and outcomes of minimally invasive prone lateral spinal surgery using a rotatable radiolucent Jackson table.

Methods: From July 2021 to June 2023, a consecutive series of patients who received minimally invasive prone lateral spinal surgery for various etiologies by the same surgical team were reviewed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!