A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Polarization fluoroimmunoassay of propazine in reversed micelles of aerosol OT in octane]. | LitMetric

The interaction between fluorescein-labeled propazine and antibodies against this hapten was studied in the reversed micelles of Aerosol OT in n-octane by a polarization fluoroassay. The effect of the hydration degree of micelles W0 (W0=[H2O]/[Surf]), which determines their size and surfactant concentration, on the binding of the antigen with antibodies was studied. A high hydration degree of the reversed micelles (W0 = 15-30) and low concentration of the surfactant (less than 50 microM) are optimal for binding. The binding efficacy depends upon the structure of the fluorescein-labeled hapten, particularly upon the length of the bridge binding fluorescein with propazine. It was shown that the polarization fluoroimmunoassay of propazine may be carried out in a reversed micellar system in nonpolar organic solvent (octane) with a detection limit of about 100 nM (20 microns/l). This is an order of magnitude higher than that achievable upon analysis in aqueous medium. The proposed polarization fluoroimmunoassay in a reversed micellar system makes it possible to detect haptens that are poorly soluble in water directly in organic extracts, e.g. in chloroform solutions.

Download full-text PDF

Source

Publication Analysis

Top Keywords

reversed micelles
12
fluoroimmunoassay propazine
8
micelles aerosol
8
hydration degree
8
polarization fluoroimmunoassay
8
reversed micellar
8
micellar system
8
reversed
5
[polarization fluoroimmunoassay
4
propazine
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!