In the last few years, new magnetic resonance (MR) pulse sequences called Fast or Turbo Spin Echo (TSE) sequences have become available. This kind of T2-weighted images is particularly useful for the study of spondylosis and degenerative spinal conditions, because it both reduces involuntary motion artifacts and its acquisition time is shorter than that of conventional SE T2-weighted images. Our study was aimed at assessing the diagnostic gain of this new type of pulse sequences in intrinsic spinal cord conditions. Therefore, we acquired TSE and conventional SE sequences, consequently, in 36 patients with intrinsic spinal cord conditions, which were apparent on T2-weighted images, and then compared the sensitivity, contrast resolution, and depiction of lesion margins and extent in both acquisition techniques. The results of our study follow: even though all lesions were identified with both techniques, contrast resolution was higher with TSE than with conventional SE images. Lesion margins and extent were substantially equally depicted with both techniques. Finally, TSE sequences had the same, and sometimes even higher, diagnostic yield than conventional SE sequences: therefore, TSE can be considered the sequence of choice in the study of intrinsic spinal cord conditions.

Download full-text PDF

Source

Publication Analysis

Top Keywords

spin echo
12
t2-weighted images
12
intrinsic spinal
12
spinal cord
12
cord conditions
12
turbo spin
8
magnetic resonance
8
pulse sequences
8
tse sequences
8
images study
8

Similar Publications

Objectives: Caffeine, a known neurostimulant and adenosine antagonist, affects brain physiology by decreasing cerebral blood flow. It interacts with adenosine receptors to induce vasoconstriction, potentially disrupting brain homeostasis. However, the impact of caffeine on blood-brain barrier (BBB) permeability to water remains underexplored.

View Article and Find Full Text PDF

: Accurate and reproducible spleen volume measurements are essential for assessing treatment response and disease progression in myelofibrosis. This study evaluates techniques for measuring spleen volume on abdominal MRI. : In 20 patients with bone marrow biopsy-proven myelofibrosis, 5 observers independently measured spleen volume on 3 abdominal MRI pulse sequences, 3D-spoiled gradient echo T1, axial single-shot fast spin echo (SSFSE) T2, and coronal SSFSE T2, using ellipsoidal approximation, manual contouring, and 3D nnU-Net model-assisted contouring comparing coefficients of variation.

View Article and Find Full Text PDF

Purpose: In primary central nervous system lymphoma (PCNSL), B-cell lymphoma-6 (BCL-6) is an unfavorable prognostic biomarker. We aim to non-invasively detect BCL-6 overexpression in PCNSL patients using multiparametric MRI and machine learning techniques.

Methods: 65 patients (101 lesions) with primary central nervous system lymphoma (PCNSL) diagnosed from January 2013 to July 2023, and all patients were randomly divided into a training set and a validation set according to a ratio of 8 to 2.

View Article and Find Full Text PDF

Fast Hadamard-Encoded 7T Spectroscopic Imaging of Human Brain.

Tomography

January 2025

NextGen Precision Health, Department of Radiology, University of Missouri Columbia, 1030 Hitt Street, Columbia, MO 65201, USA.

: The increased SNR available at 7T combined with fast readout trajectories enables accelerated spectroscopic imaging acquisitions for clinical applications. In this report, we evaluate the performance of a Hadamard slice encoding strategy with a 2D rosette trajectory for multi-slice fast spectroscopic imaging at 7T. : Moderate-TE (~40 ms) spin echo and J-refocused polarization transfer sequences were acquired with simultaneous Hadamard multi-slice excitations and rosette in-plane encoding.

View Article and Find Full Text PDF

Breath-hold T2-weighted half-Fourier acquisition single-shot turbo spin echo (HASTE) magnetic resonance imaging (MRI) of the upper abdomen with a slice thickness below 5 mm suffers from high image noise and blurring. The purpose of this prospective study was to improve image quality and accelerate imaging acquisition by using single-breath-hold T2-weighted HASTE with deep learning (DL) reconstruction (DL-HASTE) with a 3 mm slice thickness. MRI of the upper abdomen with DL-HASTE was performed in 35 participants (5 healthy volunteers and 30 patients) at 3 Tesla.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!