A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Standardization of non-invasive impedance cardiography for assessment of stroke volume: comparison with thermodilution. | LitMetric

Since its introduction by Kubicek and colleagues, impedance cardiography has been suggested as a non-invasive, simple, safe and cost-effective method of measuring stroke volume. Several controversial reports on its validity have been published. Pitfalls of this method included the nature of the electrode system and the validity of the equations. Therefore, the purpose of this study was to compare two different spot electrode arrays and the two most frequently used stroke volume equations with each other and with thermodilution. In 37 patients, 24-36 h after cardiac surgery, we performed simultaneous measurements of stroke volume with impedance cardiography (SVIC) and with thermodilution (SVTD). SVIC was obtained using the lateral spot (LS) electrode array, according to Bernstein, and a newly proposed modified semi-circular (MSC) spot electrode array. The equations of Kubicek and Sramek-Bernstein were used to calculate SVIC. The Sramek-Bernstein equation was valid only when the LS array was used; the Kubicek equation determined SVTD correctly only when the MSC array was used. However, a considerably better correlation and agreement (mean difference (2 SD)) was found between SVIC and SVTD for the latter (r = 0.90, 0.5 (17.1) ml vs r = 0.64, -4.9 (31.8) ml for the Sramek-Bernstein equation). We conclude that the most valid measurement of stroke volume using impedance cardiography was obtained when the MSC array was used together with Kubicek's equation.

Download full-text PDF

Source
http://dx.doi.org/10.1093/bja/77.6.748DOI Listing

Publication Analysis

Top Keywords

stroke volume
20
impedance cardiography
16
spot electrode
12
volume impedance
8
electrode array
8
sramek-bernstein equation
8
msc array
8
stroke
5
volume
5
array
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!