The electrochemical determination of zinc arising from zinc-insulin complexes was investigated and it was demonstrated that zinc in zinc-insulin solution can be measured in the presence of dissolved oxygen by square-wave anodic stripping voltammetry (SWASV) at mercury thin-film electrodes on glassy carbon disc minielectrode and cylindrical carbon fibre microelectrode substrates. Reoxidation signals arise from complexed zinc at low insulin concentrations (< 100 nmol l-1) and from labile zinc at higher concentrations; the latter can be quantified through linear calibration curves. Batch injection analysis with SWASV was successfully tested for the determination of zinc in zinc-insulin solutions in small sample volumes. Since intracellularly stored insulin exists in the form of a zinc-insulin complex, these techniques are very promising for the indirect study of insulin release from pancreatic beta-cells.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1039/an9962101789 | DOI Listing |