Purpose: To assess the diagnostic value of the recovery phase patterns of the ST-segment depression in patients referred for chest pain.

Patients And Methods: Continuous plots of ST-segment depression against heart rate during exercise and recovery were constructed within a population of 160 consecutive symptomatic patients who all had undergone catheterization (80 with > or = 1 stenosis > or = 50%). We used a new quantitative method of measurement allowing all kinds of rate recovery loops (even the so-called "intermediate" loops) to be considered for analysis. The measurements of the heart rate (HR)-adjusted ST-segment depression were performed at 20 and 60 ms from the J point, providing two different values of a quantified recovery loop index (RLI): RLI 20 and RLI 60.

Results: Both RLI showed a higher specificity (0.81 +/- 0.04 and 0.74 +/- 0.05, respectively) than did the standard criterion (0.65 +/- 0.10), but the difference was significant regarding RLI 20 only (P = 0.011). As to the sensitivity, no significant differences were found among all of the criteria (0.74 +/- 0.05, 0.80 +/- 0.04, 0.76 +/- 0.05, respectively). The timing of measurements of the RLI within the repolarization phase did not affect their overall accuracy (0.77 +/- 0.03 for both RLI). The values of the receiver-operating characteristic (ROC) curve areas were significantly greater for both RLI (0.83 +/- 0.06 and 0.84 +/- 0.06 respectively) than for the standard criterion (0.75 +/- 0.07; P < 0.02). Finally, both RLI allowed to differentiate accurately the study subjects according to the number of diseased vessels, whereas the standard criterion could only distinguish between CAD patients and subjects with normal angiograms.

Conclusion: The quantitative analysis of the rate recovery phase patterns appears to be useful for the diagnosis of coronary heart disease and the assessment of its severity in symptomatic patients.

Download full-text PDF

Source
http://dx.doi.org/10.1016/S0002-9343(96)00302-6DOI Listing

Publication Analysis

Top Keywords

st-segment depression
16
recovery phase
12
phase patterns
12
+/- 005
12
standard criterion
12
+/-
10
rli
9
quantitative analysis
8
patterns st-segment
8
diagnosis coronary
8

Similar Publications

Background: While viruses remain the leading cause of infectious myocarditis, improved diagnostic methods have highlighted the role of bacteria as a possible cause. We report two cases of myocarditis as a complication of infection.

Case Summaries: Patient A, a 17-year-old Caucasian male with a history of asthma, presented to the emergency department (ED) after experiencing fever and nausea for four days, followed by 1 day of diarrhoea and chest discomfort.

View Article and Find Full Text PDF

Pregnancy-related spontaneous coronary artery dissection (P-SCAD) is a life-threatening condition that occurs during or after pregnancy, is rare and can be overlooked. It is one of the most important causes of pregnancy-related acute myocardial infarction. A 25-year-old female patient was admitted with a complaint of chest pain in her 37th week of pregnancy.

View Article and Find Full Text PDF

Background: Recently it has been suggested that coronary microvascular dysfunction (CMD) may explain the high false-positive rate of exercise electrocardiographic stress testing (EST). However, patients with angina but non-obstructive coronary artery disease (ANOCA) present with a broader spectrum of coronary vasomotor dysfunction (CVDys), namely coronary artery spasm (CAS), CMD or a combination of both. We aim to investigate the diagnostic value of EST for the entire CVDys spectrum.

View Article and Find Full Text PDF

To assess the effectiveness of transcatheter aortic valve replacement (TAVR) on electrocardiographic remodeling in patients with severe aortic stenosis (AS), and identify its influencing factors. A cohort study was conducted on patients with a confirmed diagnosis of severe AS who successfully underwent TAVR at the Second Affiliated Hospital of Dalian Medical University between June 2018 and March 2023. Data, including standard 15-lead electrocardiograms and echocardiograms, were collected before the operation, 1 week after the operation, and 3 months after the operation.

View Article and Find Full Text PDF

Diagnostic accuracy of low-dose myocardial perfusion imaging in a real-world setting.

J Nucl Cardiol

January 2025

Université de Lorraine, CHRU-Nancy, Department of Nuclear Medicine and Nancyclotep Imaging Platform, Nancy, F-54000, France; Université de Lorraine, INSERM U1254, IADI, Nancy, F-54000, France. Electronic address:

Background: This large-scale study analyzes factors affecting the diagnostic accuracy of low-dose myocardial perfusion imaging and correlation with coronary angiography in a real-world practice.

Methods: We compared data extracted from routine reports of (i) low-dose [Tc]sestamibi stress-MPI performed with no attenuation correction and predominantly exercise stress testing and (ii) the corresponding coronary angiography.

Results: We considered 1070 pairs of coronary angiography/stress-MPI results reported by 11 physicians.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!