Catheter migration of a Port-a-cath system.

Cardiovasc Intervent Radiol

Department of Radiology, Hôpital Civil de Charleroi, Belgium.

Published: March 1997

A patient with axillary venous thrombosis caused by lymph node compression and the presence of a displaced catheter in the vascular lumen is presented. In this case, percutaneous interventional radiological procedures (balloon angioplasty and snare loop method) in conjunction with medical treatment were effective in limiting the post-thrombotic syndrome and restoring the proper positioning of the catheter, thereby saving the central venous access.

Download full-text PDF

Source
http://dx.doi.org/10.1007/BF02577634DOI Listing

Publication Analysis

Top Keywords

catheter migration
4
migration port-a-cath
4
port-a-cath system
4
system patient
4
patient axillary
4
axillary venous
4
venous thrombosis
4
thrombosis caused
4
caused lymph
4
lymph node
4

Similar Publications

Worsening spasticity due to catheter breakage during intrathecal baclofen therapy: a case report.

J Med Case Rep

January 2025

Department of Orthopedic Surgery, Graduate School of Medicine, Kanazawa University, 13-1 Takara-machi, Kanazawa City, Ishikawa, 920-8641, Japan.

Background: Intrathecal baclofen therapy can substantially improve symptoms in patients with severe spasticity owing to traumatic spinal cord injury, multiple sclerosis, cerebral paresis, or tethered cord syndrome. Problems associated with intrathecal catheters include migration, laceration, occlusion, or disconnection. Several case reports have described the management of catheter fragments.

View Article and Find Full Text PDF

The use of the snare catheter (SC) technique has been described in the field of interventional cardiology, in particular in the retrieval of a lost device, for example, a dislodged coronary stent, broken coronary wire, and so forth. In the transcatheter aortic valve replacement (TAVR) procedure, some cases have been observed where the anatomy is challenging or there are scenarios where some complications occur during the procedure, which make it necessary to use some tools to achieve the success of the procedure. The SC has shown are very useful either to achieve the ascent of the valve to the annular plane in complex anatomies or as a rescue measure in the event of complications that may arise after valve implantation.

View Article and Find Full Text PDF

The integration of self-expandable nitinol frames with cable-driven parallel mechanisms offers a promising advancement in minimally invasive cardiovascular interventions. This study presents the design, fabrication, and verification of a miniaturized self-expandable nitinol frame to enhance catheter tip steerability and navigation within complex vascular anatomies. The frame is reduced in size for delivery through 7-8 Fr sheaths while accommodating diverse vascular diameters, allowing up to a maximum expansion of 15 mm.

View Article and Find Full Text PDF

Removal of spontaneously fractured leads with their proximal ends migrated into the vascular space has not been analysed in detail thus far. The study aimed to compare the effectiveness of different approaches and auxiliary tools for removing fractured leads with migrated proximal ends. Retrospective analysis of 72 cases from a database containing 3847 TLEs (transvenous lead extraction).

View Article and Find Full Text PDF