Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
A new turbidimetric inhibition immunoassay for digoxin (Tina-quant [a] Digoxin, Boehringer Mannheim) was evaluated in seven laboratories. It can be performed without sample pretreatment with ready-to-use reagents on nondedicated analyzers in combination with routine clinical chemistry. The studies revealed a good analytical performance: lower limit of detection 0.12 microg/L (3 SD from mean of blank); linearity up to 7.5 microg/L; median between-run CVs 8.1% (0.6 microg/L), 2.8% (1.5 microg/L), 1.9% (3 microg/L); mean analytical recovery in control sera 98-102%; slopes from 0.97 to 1.09 and intercepts from -0.28 to 0.10 microg/L in comparison with four immunoassays; and a high resistance to common interferents. The test was more resistant to digoxin-like immunoreactive factor (DLIF) interference than other methods, showing cross-reactivity only in some intensive care patient samples. Among 192 patients in whom DLIF is expected (e.g., pregnant women, patients with renal failure, newborns), 90% of results were < or =0.26 microg/L digoxin. Cortisol showed no cross-reactivity and digoxigenin had a low reactivity. An interlaboratory survey revealed a good comparability of the Tina-quant [a] test with the median of all methods (slope 0.99, intercept -0.06 microg/L). An HPLC method for digoxin based on isocratic separation of samples on an RP-18 column followed by detection by an immunoassay yielded a reasonable comparability with the immunochemical tests with noncritical samples. Divergent results of immunoassays caused by DLIFs or different cross-reactivities with digoxin metabolites or derivatives can be explained by the use of this HPLC method.
Download full-text PDF |
Source |
---|
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!