Objective: This study examined the movement of the soluble ion technetium Tc 99m across the ovine placenta and intramembranous pathway.
Study Design: Nineteen fetal sheep at 131 +/- 1 (SE) days' gestation were studied. After a 1-hour control period technetium Tc 99m was injected into either a fetal vein (n = 7), the amniotic cavity (n = 5), or a maternal vein (n = 5). Maternal and fetal blood, fetal urine, and amniotic and allantoic fluid were sampled during the control period and for 8 hours after the injection. Fetal urine was drained externally throughout the experiment. In five animals technetium Tc 99m was injected intraamniotically after the fetus was killed with air emboli and sampled as described.
Results: Intrafetally injected technetium Tc 99m rapidly crossed the placenta; then it entered and was concentrated in the amniotic cavity. Intraamniotically injected technetium Tc 99m rapidly entered into the fetal circulation. The maternally injected technetium Tc 99m rapidly crossed the placenta into the fetus, suggesting a half-time for placental exchange of < 50 minutes. The technetium Tc 99m injected into the dead fetus group demonstrated significantly less maternal absorption than in the live fetus group.
Conclusions: The soluble ion technetium Tc 99m demonstrated a much more rapid movement in both directions across the ovine placenta then previously demonstrated for the smaller ion sodium. Technetium Tc 99m rapidly crossed the intramembranous pathway bidirectionally, suggesting a high permeability of the intramembranous pathway. Minimal maternal absorption of technetium Tc 99m in the dead fetus group suggests little transmembranous absorption by the mother.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/s0002-9378(96)70106-0 | DOI Listing |
Neurogastroenterol Motil
January 2025
Division of Gastroenterology and Hepatology, Mayo Clinic, Rochester, Minnesota, USA.
Background: The carbon-13 spirulina gastric emptying breath test (GEBT) is approved to identify delayed, but not accelerated, gastric emptying (GE). We compared the utility of the GEBT to scintigraphy for diagnosing abnormal GE in patients with diabetes mellitus.
Methods: Twenty-eight patients with diabetes ate a 230-kcal test meal labeled with technetium 99 m and C-spirulina, after which 10 scintigraphic images and breath samples (baseline, 15, 30, 45, 60, 90, 120, 150, 180, 210, and 240 min) were collected on 2 occasions 1 week apart.
Appl Radiat Isot
January 2025
Medical Diagnostic Imaging Department, College of Health Science, University of Sharjah, Sharjah, United Arab Emirates.
Background: Bone scans using technetium-99m methylene diphosphonate (99mTc-MDP) are widely used in nuclear medicine for diagnosing various bone disorders. However, the radiation exposure associated with these procedures necessitates careful consideration and optimization.
Aim: This study aimed to evaluate radiation doses in terms of Effective Dose (ED) and establish Diagnostic Reference Levels (DRLs) for 99mTc-MDP bone scans in Saudi Arabia.
J Mol Graph Model
January 2025
"VINČA" Institute of Nuclear Sciences - National Institute of the Republic of Serbia, University of Belgrade, 11001, Belgrade, Serbia.
Technetium-99m plays a pivotal role in nuclear medicine, offering unique IMAGING capabilities due to its favorable physical and chemical properties. This study investigates the redox behavior and electronic structures of three representative Tc(V) oxo complexes, [TcO(HMPAO)], [TcO(Bicisate)], and [TcO(DMSA)], using computational techniques. Employing relativistic density functional theory with the Zero-Order Regular Approximation (ZORA), we analyze singlet-triplet energy gaps, Gibbs free energy changes, and redox potentials in neutral and acidic environments.
View Article and Find Full Text PDFPharmaceutics
January 2025
Laboratory of Nuclear Medicine (LIM-43), Hospital das Clinicas HCFMUSP, Faculdade de Medicina, Universidade de Sao Paulo, Sao Paulo 05403-911, SP, Brazil.
Background/objectives: Dithiocarbazates (DTCs) and their metal complexes have been studied regarding their property as anticancer activities. In this work, using S-benzyl-5-hydroxy-3-methyl-5-phenyl-4,5-dihydro-1H-pirazol-1-carbodithionate (Hbdtc), we prepared [ReO(bdtc)(Hbdtc)] and [[Tc]TcO(bdtc)(Hbdtc)] complexes for tumor uptake and animal biodistribution studies.
Methods: Re complex was prepared by a reaction of H2bdtc and (NBu)[ReOCl], the final product was characterized by IR, H NMR, CHN, and MS-ESI.
Cir Esp (Engl Ed)
January 2025
Consorcio Sanitario del Maresme, Hospital de Mataró, Mataró, Spain.
Introduction: Sentinel lymph node (SLN) detection is the technique of choice for staging early-stage breast cancer (BC). The preferred technique for SLN detection is labeling with the radioisotope Technetium-99 (Tc-99). Other methods have been evaluated, including methylene blue, magnetic tracers, iodine seeds, or fluorescent substances.