Under standard conditions double contrast barium enema (DCBE) was carried out on a selected patient cohort using either standard (1.5 mA) or low (0.5 mA) fluoroscopic current. A statistically significant (p < or = 0.01) reduction in total dose was achieved by use of low screening current. This reduction was of the order of 40%. Fluoroscopic image quality was analysed both objectively and subjectively, and was found not to be significantly degraded when the lower current was used. On blinded evaluation all examinations were found to be of diagnostic quality. The use of low fluoroscopic current results in a reduction in patient dose, without compromising fluoroscopic image quality or diagnostic standard of the examination. Low fluoroscopic current technique has been adopted as the standard in our department.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1259/0007-1285-69-825-852 | DOI Listing |
Quant Imaging Med Surg
January 2025
Department of Diagnostic Radiology, First Medical Center of the Chinese PLA General Hospital, Beijing, China.
Background: Traditional freehand puncture relies on non-real-time computed tomography (CT) images, which significantly affects the accuracy of puncturing targets in the lower lung lobes with respiratory motion. This study aims to assess the safety and feasibility of a teleoperated robotic system and low-dose CT for the accurate real-time puncture of targets in the lungs of live pigs during breathing under fluoroscopic guidance.
Methods: Two puncture methods were analyzed: freehand and robot-assisted.
J Clin Med
December 2024
Department of Materials and Production, Aalborg University, 9220 Aalborg, Denmark.
: Spinal flexibility radiographs are important in adolescent idiopathic scoliosis (AIS) for clinical decision-making. In this study, we introduce a new method, the 'quantitatively controlled standing fulcrum side-bending' test (CSFS test). This is a feasibility study; we aimed to quantify the applied force and track the temporospatial changes in the spine specifically by measuring the continuous change in the Cobb angle (in degrees) during lateral bending.
View Article and Find Full Text PDFFront Vet Sci
December 2024
Department of Clinical Sciences and James L. Voss Veterinary Teaching Hospital, College of Veterinary Medicine and Biomedical Sciences, Colorado State University, Fort Collins, CO, United States.
Objective: To determine procedural feasibility, safety, and short-term efficacy in dogs with severe degenerative mitral regurgitation (MR) undergoing transcatheter edge-to-edge repair (TEER) with a canine-specific device.
Design: Prospective, single-arm (uncontrolled), single-institution clinical feasibility study.
Animals: Fifty client-owned dogs with severe degenerative MR operated over a 28-month period.
Interv Pain Med
December 2024
Department of Rehabilitation, Thomas Jefferson University Hospital, Philadelphia, PA, USA.
A 78-year-old female with a remote history of L3-4 decompression and fusion presented with several months of low back and radicular leg pain. MRI revealed moderate L2-L3 spinal canal stenosis, ligamentum flavum infolding, moderate bilateral foraminal stenosis, and a grade I retrolisthesis. A right sided L2-L3 TFESI was performed using multiplanar fluoroscopic imaging with a subpedicular supraneural approach.
View Article and Find Full Text PDFInterv Pain Med
December 2024
University of Rochester Medical Center10, 601 Elmwood Avenue, Rochester, NY, 14623, USA.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!