Infection around metallic implants is a rare but severe complication of orthopaedic surgery. A novel animal model mimicking conditions of internal fixation devices was developed to evaluate the role of host proteins adsorbed on metallic devices in promoting adhesion and colonization of the material surfaces by Staphylococcus aureus. Small plates made of pure titanium were either fixed (three screws per plate) onto the iliac bones of guinea pigs or implanted into their subcutaneous space as controls. Five to 6 weeks after surgery, the plates and screws were removed from the previously killed animals, carefully rinsed in buffer, and tested in an in vitro assay of S. aureus adhesion to metallic surfaces. To evaluate the role of fibronectin in staphylococcal adhesion to explanted plates and screws, a mutant of S. aureus that is specifically defictive in fibronectin adhesion due to decreased expression of the fibronectin adhesin was compared with its isogenic parental strain. A significant reduction in adhesion of the fibronectin adhesin-defective mutant compared with the parental strain occurred on both the subcutaneously implanted and bone-implanted metallic plates. The results of this specific biological assay suggest that fibronectin is present on bone-implanted metallic devices and promotes attachment of S. aureus to their surfaces. This novel experimental model should help, to characterize several parameters of bacterial adhesion to metallic orthopaedic devices and to develop novel anti-adhesive strategies for preventing such infections.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/jor.1100140611 | DOI Listing |
Biomed Res Int
February 2021
IRCCS Istituto Ortopedico Rizzoli, Laboratory of Biomechanics and Technology Innovation, Bologna, Italy.
The growing incidence of degenerative musculoskeletal disorders as well as lifestyle changes has led to an increase in the surgical procedures involving implanted medical devices in orthopedics. When studying implant/tissue interface in hard materials (i.e.
View Article and Find Full Text PDFChin Med J (Engl)
January 2019
Department of Orthopedic, The Third Affiliated Hospital of Southern Medical University, Guangzhou, Guangdong 510630, China.
Background: Some porous materials have been developed to enhance biologic fusion of the implants to bone in spine fusion surgeries. However, there are several inherent limitations. In this study, a novel biomedical porous tantalum was applied to in vitro and in vivo experiments to test its biocompatibility and osteocompatibility.
View Article and Find Full Text PDFBiomed Res Int
February 2017
Department of Orthopaedics, First Hospital of China Medical University, 155 Nan Jing Bei Street, Heping District, Shenyang 110001, China.
Background. Early radiological diagnosis and continual monitoring are of ultimate importance for timely treatment of delayed union, nonunion, and infection after bone fracture surgery. Although magnetic resonance imaging (MRI) could provide superior detailed images compared with X-ray and computed tomography (CT) without ionizing radiation, metal implants used for fracture fixation lead to abundant artifacts on MRI and thus prohibit accurate interpretation.
View Article and Find Full Text PDFDirect transcutaneous prosthetic attachment (osseointegration) consists of implanting directly into the residuum bone a metal pylon whose external fraction connects the residuum to the external prosthesis. Since the introduction of osseointegration about 20 years ago, the obvious challenge associated with this technology has been the skin-pylon interface as a source of infections. In comparison, the bone-device interface was considered less problematic because of the knowledge and experience inherited from dental implantology and total joint replacement (arthroplasty).
View Article and Find Full Text PDFNeurosurgery
July 2006
Department of Neurosurgery, Toulouse University Hospitals, Toulouse-Rangueil, France.
Objective: Very few studies have attempted to quantify the true (application) accuracy of image-guidance systems during craniotomy. This is, in part, because of the lack of millimetric intraoperative targets to allow such measurements. Few in vivo studies have compared the influence of mode of patient registration on subsequent true accuracy.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!