The aim of this study was to investigate the accuracy of quantitative one-day exercise-rest 99mTc tetrofosmin tomography in the identification of patients with suspected coronary artery disease (CAD) and in the detection of single stenosed coronary vessels. Sixty-one patients with suspected CAD and submitted to coronary angiography were examined. All patients were given 2 i.v. injections of 99mTc tetrofosmin, one at peak exercise (370 MBq) and the other (1110 MBq) at rest 3 hours after exercise (images 15-30 min after injection for both studies). All patients with CAD (> or = 50% luminal stenosis) (n = 50) had abnormal 99mTc tetrofosmin tomogram (100% sensitivity). Only one patient without CAD had abnormal 99mTc tetrofosmin tomogram (91% specificity). Overall sensitivity, specificity, and diagnostic accuracy in the detection of single stenosed vessels were 77%, 93% and 85%, respectively. No significant differences among single vascular areas were observed. Sensitivity and diagnostic accuracy in the identification of single stenosed coronary vessels were significantly higher (p < 0.05) in the patients with single-vessel disease (n = 21) than in those with multivessel disease (n = 29). Sensitivity, specificity and diagnostic accuracy in detecting single diseased vessels were similar in the patients without (n = 26) and in those with previous myocardial infarction (n = 35). The results of this study demonstrate that quantitative one-day exercise-rest 99mTc tetrofosmin SPECT imaging is a suitable and accurate technique to identify patients with suspected CAD and to detect single stenosed coronary vessels.
Download full-text PDF |
Source |
---|
J Nucl Med Technol
December 2024
Department of Nuclear Medicine, University Medical Centre Ljubljana, Ljubljana, Slovenia; and.
Various techniques have been used in attempts to reduce interfering gastrointestinal activity in myocardial perfusion imaging (MPI); however, these approaches have yielded inconsistent results. The goal of this study was to investigate the efficacy of monitored walking, a previously unexplored technique, in reducing subdiaphragmatic activity-related artifacts during pharmacologic stress Tc-tetrofosmin MPI with SPECT to improve the overall image quality. The study included patients who underwent MPI with pharmacologic stress.
View Article and Find Full Text PDFJ Nucl Med Technol
September 2024
Nuclear Medicine Section, Department of Radiology, King Abdul-Aziz University Hospital, Jeddah, Saudi Arabia.
Myocardial perfusion imaging (MPI) provides physiologic and functional information about the heart muscle and its blood flow. Extracardiac radioactivity can interfere with visualization of the inferior wall of the myocardium, leading to poor-quality images, difficulties in interpretation, and delays in routine practice. This study aimed to identify the efficiency of having the patient consume a carbonated lemon drink to minimize the extracardiac radioactivity of Tc-sestamibi in comparison to Tc-tetrofosmin during MPI.
View Article and Find Full Text PDFCan J Cardiol
March 2024
Department of Diagnostic and Interventional Radiology, Hokkaido University Hospital, Sapporo, Japan; Department of Diagnostic Imaging, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Sapporo, Japan.
Myocardial perfusion scintigraphy is a popular minimally invasive method for evaluating chronic coronary disease (CCD). We performed myocardial scintigraphy to assess CCD in a 74-year-old man with a history of allergy to contrast media. The patient developed anaphylactic shock immediately after the administration of the technetium (Tc)-tetrofosmin preparation.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!