A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Determination of glomerular filtration rate with Visipaque in patients with severely reduced renal function. | LitMetric

AI Article Synopsis

  • Iodixanol and iohexol are two types of contrast media used to measure glomerular filtration rate (GFR) in patients with severely impaired kidney function.
  • The study involved 16 patients with high creatinine levels, comparing different GFR measurement methods using these contrast agents and analyzing their accuracy.
  • Results showed that simpler methods (Bröchner-Mortensen and single-sample) provided reliable GFR estimates, similar to conventional methods, although some overestimation occurred due to non-kidney excretion of the contrast media.

Article Abstract

Iodixanol (Visipaque, Nycomed Imaging AS, Oslo, Norway), and isotonic, dimeric and non-ionic contrast medium (CM), and iohexol (Omnipaque, Nycomed Imaging AS, Oslo, Norway), a low-osmolar, monomeric and non-ionic contrast medium, were used as glomerular filtration rate (GFR) markers in patients with severely impaired renal function. Different methods for determining GFR were compared. A total of 16 patients with s-creatinine > 400 mumol/l were enrolled in the study; 8 in each CM group. Serum-iodine was measured, and plasma CM clearance was determined using the Bröchner-Mortensen method, the single-sample method and conventional method. The ratios between the results obtained from the conventional method and each of the two other methods were calculated. These data were plotted against the mean of the pairs compared, and the upper and lower limits of agreement were calculated as the mean ratio +/- 2SD. The comparison showed a high degree of agreement between methods, and the two simpler methods seem to be good alternatives to the conventional method, which gave good estimates of GFR (vs that determined by means of renal 125I-iothalamate clearance) when 24-h blood samples were included. However, slight overestimations of GFR, due to extrarenal excretion of the CM, were observed. In summary, serum clearance of iodixanol, as determined by the Bröchner-Mortensen method or single-sample method seems to be a simple and accurate marker for GFR in patients with severely reduced renal function. The findings obtained with iodixanol were similar to those obtained with iohexol.

Download full-text PDF

Source
http://dx.doi.org/10.1007/BF00240692DOI Listing

Publication Analysis

Top Keywords

patients severely
12
renal function
12
conventional method
12
glomerular filtration
8
filtration rate
8
severely reduced
8
reduced renal
8
nycomed imaging
8
imaging oslo
8
oslo norway
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!